231 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정재원-
dc.date.accessioned2020-10-28T02:11:15Z-
dc.date.available2020-10-28T02:11:15Z-
dc.date.issued2019-11-
dc.identifier.citation한국생태환경건축학회 학술발표대회 논문집, v. 19, no. 2, Page. 140-141en_US
dc.identifier.issn1975-3616-
dc.identifier.urihttp://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE09265186-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/155032-
dc.description.abstractAlthough Korean government tried to enact the law about mandatory pre-heat coil installation in Energy Recovery Ventilator(ERV), the plan was withdrawn due to the concern about excessive energy consumption. Therefore, the other alternative concerning real-time climate difference and effectiveness difference about the pre-heater regulation has been required to prevent the condensation problem. This study suggests a real-time control criterion applying the frost threshold temperature. With the new control measure, not only the energy consumption of pre-heat coil decreased by 61% from the previous suggested method, but also 31% less coil capacity was needed for operation in order to preclude the condensation problem.en_US
dc.description.sponsorship이 연구는 2019년도 한국연구재단 연구비 지원에 의한 결과의 일부임. 과제번호:2019R1A2C2002514. 또한, 이 연구는 2019년 도 한국에너지기술평가원 연구비 지원에 의한 결과의 일부임. 과제번호:20184010201710.en_US
dc.language.isoko_KRen_US
dc.publisher한국생태환경건축학회en_US
dc.subject전열교환 환기장치en_US
dc.subject결로en_US
dc.subject결빙en_US
dc.subject예열코일en_US
dc.subjectEnergy Recovery Ventilatoren_US
dc.subjectCondensationen_US
dc.subjectFrosten_US
dc.subjectPre-heat Coilen_US
dc.title전열교환 환기장치의 효율을 고려한 결로 방지용 예열 온도 예측 모델 개발en_US
dc.title.alternativeDevelopment of Pre-heat Temperature Prediction Model for Condensation Prevention regarding Effectiveness of Energy Recovery Ventilatoren_US
dc.typeArticleen_US
dc.relation.no2-
dc.relation.volume19-
dc.relation.page140-141-
dc.contributor.googleauthor고진영-
dc.contributor.googleauthor정재원-
dc.contributor.googleauthorKo, Jinyoung-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE