296 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김용수-
dc.date.accessioned2020-07-06T02:23:31Z-
dc.date.available2020-07-06T02:23:31Z-
dc.date.issued2019-12-
dc.identifier.citationNUCLEAR ENGINEERING AND TECHNOLOGY, v. 51, no. 8, Page. 1951-1956en_US
dc.identifier.issn1738-5733-
dc.identifier.urihttps://linkinghub.elsevier.com/retrieve/pii/S1738573319301639-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/151660-
dc.description.abstractAs a part of the preliminary decommissioning plan of KEPCO-NF fuel fabrication facility, DCGLs of three target radionuclides, U-234, U-235, and U-238, were derived using RESRAD-BUILD code and contaminated areas of the facility were classified based on contamination levels from the derived DCGLs. From code simulations, one-room modeling results showed that the grinding room in building #2 was the most restrictive (DCGL(gross) 10493.01 Bq/m(2)). The DCGL(gross) results in contaminated areas from one-room modeling were slightly more conservative than three-room modeling. Prior to the code simulation, field survey and measurements conducted by each survey unit. For a conservative approach, the most restrictive DCGL(gross) in each survey unit was taken as a reference to classify the contaminated areas of the facility. Accordingly, seven rooms and 37 rooms in the nuclear-fuel buildings were classified as Class 1 and Class 2, respectively. As expected, fuel material handling and processing rooms such as the grinding room, sintering room, compressing room, and powder collecting room were included in the Class 1 area. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.en_US
dc.description.sponsorshipThis work was supported by a National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIP: Ministry of Science, ICT, and Future Planning) (No. NRF-2017M2B2B1072888) and by the Human Resources Program in Energy Technology of the Korea Institute of Energy Technology Evaluation and Planning (KETEP), granted financial resources from the Ministry of Trade, Industry, & Energy, Republic of Korea (No. 20184030201970).en_US
dc.language.isoenen_US
dc.publisherKOREAN NUCLEAR SOCen_US
dc.subjectDCGLen_US
dc.subjectDecommissioningen_US
dc.subjectNuclear fuel fabrication facilityen_US
dc.subjectRESRAD-BUILDen_US
dc.subjectMARSSIMen_US
dc.titleA study on DCGL determination and the classification of contaminated areas for preliminary decommission planning of KEPCO-NF nuclear fuel fabrication facilityen_US
dc.typeArticleen_US
dc.relation.no8-
dc.relation.volume51-
dc.identifier.doi10.1016/j.net.2019.06.012-
dc.relation.page1951-1956-
dc.relation.journalNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.contributor.googleauthorCho, Seo-Yeon-
dc.contributor.googleauthorKim, Yong-Soo-
dc.contributor.googleauthorPark, Da-Won-
dc.contributor.googleauthorPark, Chan-Jun-
dc.relation.code2019044544-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidyongskim-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE