dc.description.abstractThis study investigated the applicability of a liquid desiccant assisted dedicated outdoor air system (LDADOAS) with organic Rankine cycle (ORC) to high-rise apartment building as a centralized ventilation system. A existing DOAS is used for reference system to compare the energy benefit analysis. The LDADOAS is consisted of liquid desiccant system and indirect evaporative cooler, and uses 100% of outdoor air as ventilation. A Novec 649 and district heat source was used as a working refrigerant and heat source, respectively. A electrical power produced by the ORC is used to a common electricity in apartment building. A waste heat source from the ORC is used to solution heating at the regenerator in the LDADOAS. The result showed that the LDADOAS with ORC saved 63.6% of primary energy compare with reference DOAS despite of three times of energy demands. Consequently, the proposed system has energy benefit than reference ventilation system because of the use of the waste heat source from the ORC.en_US
dc.description.sponsorship본 연구는 2019년도 미래창조과학부의 재원으로 한국연구재단의 지원을 받아 수행한 연구 과제 입니다. (No.2019R1A2C2002514). 또한, 본 연구는 2019년도 국토교통과학기술진흥원의 재원으로 국토교통기술촉진연구사업의 지원을 받아 수행한 연구 과제입니다. (No.19CTAP-C141826-02). 또한, 본 연구는 2019년 산업통상자원부의 재원으로 한국에너지기술평가원의 지원을 받아 수행한 연구 과제 입니다.(No. 20184010201710).en_US
dc.language.isoko_KRen_US
dc.publisher(사)대한설비공학회en_US
dc.subject유기 랭킨 사이클en_US
dc.subject중앙환기시스템en_US
dc.subject액체식 제습 시스템en_US
dc.subject외기전담 시스템en_US
dc.subjectOrganic Rankine cycleen_US
dc.subjectCentral ventilation systemen_US
dc.subjectLiquid desiccanten_US
dc.subjectDedicated outdoor air systemen_US
dc.title외기전담시스템과 제습증발냉각 환기시스템의 공동주택 중앙환기에 대한 적용성 분석en_US
dc.title.alternativeApplicability analysis of a liquid desiccant assisted dedicated outdoor air system as a central ventilation systemen_US
dc.typeArticleen_US
dc.relation.page260-263-
dc.contributor.googleauthor김범준-
dc.contributor.googleauthor박준영-
dc.contributor.googleauthor윤수열-
dc.contributor.googleauthor정재원-
dc.contributor.googleauthorKim, Beom-Jun-
dc.contributor.googleauthorPark, Joon-Young-
dc.contributor.googleauthorYoon, Soo-Yeol-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE