351 0

Rate Allocation for Multi-Layered Aquifer in Commingled CO2 Injection Well

Title
Rate Allocation for Multi-Layered Aquifer in Commingled CO2 Injection Well
Author
송영수
Alternative Author(s)
송영수
Advisor(s)
성원모
Issue Date
2020-02
Publisher
한양대학교
Degree
Master
Abstract
Most deep saline aquifers consist of multiple layers, and CO2 is generally injected through the injection well in a commingled form with one tubing string. Layer thicknesses and physical properties such as permeability and porosity vary from layer to layer because of differences in lithology and mineral compositions. When a heterogeneity such as a fault exists, if CO2 is rapidly introduced first into a certain layer, this CO2 reaches fault faster than other layers. Therefore, it is necessary to consider characteristics of multi-layer aquifer in CO2 storage. In this study, rate allocation by layer was calculated in the multi-layered Pohang Basin aquifer, Korea, and whether CO2 reaches the fault and the pore pressure at the fault exceeds the fault reactivation pressure were investigated to evaluate the stability of the aquifer. In addition, the maximum CO2 storage capacity of the aquifer was estimated and we observed changes in trapping mechanisms over a 1,000 year period after the cessation of injection. The results of the analysis indicate that when up to 50 kton of CO2 was injected into the Pohang Basin multi-layered aquifer over 2 years, the rate allocations of the upper and lower layers were 70% and 30%, respectively. CO2 did not reach to the closest EF1 fault, and the pore pressure at this fault did not exceed the fault reopening pressure. The maximum possible storage capacity was conservatively calculated under the conditions of fault reactivation pressure (11.7 MPa) and maximum compressor capacity (14 MPa), indicating that a total of 160 kton can be stably injected over six years without reaching the fault. In order to evaluate the stability of the aquifer, the changes in trapping mechanisms over a 1,000 year period were observed. According to the results, structural trapping decreased drastically, from 64.7% to 4.5%, over 1000 years. Meanwhile, solubility and residual trapping increased significantly, from 35.3% to 95.5%. Therefore, the data analyzed to date indicate that the project injecting CO2 in a commingled form from single tubing in the multi-layered Pohang Basin aquifer, Korea, has no possibility of CO2 leakage due to fault reopening.
URI
https://repository.hanyang.ac.kr/handle/20.500.11754/123682http://hanyang.dcollection.net/common/orgView/200000437030
Appears in Collections:
GRADUATE SCHOOL[S](대학원) > EARTH RESOURCES AND ENVIRONMENTAL ENGINEERING(자원환경공학과) > Theses (Master)
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE