249 116

Full metadata record

DC FieldValueLanguage
dc.contributor.author안강호-
dc.date.accessioned2020-01-22T06:47:25Z-
dc.date.available2020-01-22T06:47:25Z-
dc.date.issued2019-01-
dc.identifier.citationPARTICLE AND FIBRE TOXICOLOGY, v. 16, Article no. 2en_US
dc.identifier.issn1743-8977-
dc.identifier.urihttps://link.springer.com/article/10.1186/s12989-018-0286-9-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/122212-
dc.description.abstractBackgroundInformation on particle deposition, retention and clearance are important for the evaluation of the risk of inhaled nanomaterials to human health. Recent revised OECD inhalation toxicity test guidelines require to evaluate the lung burden of nanomaterials after rodent subacute and subchronic inhalation exposure (OECD 412, OECD 413). These revised test guidelines require additional post-exposure observation (PEO) periods that include lung burden measurements that can inform on lung clearance behavior and translocation. The latter being particularly relevant when the testing chemical is a solid poorly soluble nanomaterial. Therefore, in the spirit of 3 R's, we investigated whether measurement of retained lung burden of inhaled nanoparticles (NPs) in individual lung lobes is sufficient to determine retained lung burden in the total lung. If it is possible to use only one lobe, it will reduce animal use and maximize the number of endpoints evaluated.ResultsTo achieve these goals, rats were exposed nose-only for 1 or 5days (6h/day) to an aerosol of 20nm well-dispersed silver nanoparticles (AgNPs), which is the desired particle diameter resulting in maximum deposition in the pulmonary region when inhaled as singlets. After exposure, the five lung lobes were separated and silver concentration was measured using inductively coupled plasma-mass spectrophotometer (ICP-MS). The results showed that the retention of deposited silver nanoparticle in the different lung lobes did not show any statistically significant difference among lung lobes in terms of silver mass per gram lung lobe. This novel finding of evenness of retention/deposition of inhaled 20nm NPs in rats for all five lobes in terms of mass per unit tissue weight contrasts with earlier studies reporting greater apical lobe deposition of inhaled micro-particles in rodents. The difference is most likely due to preferred and efficient deposition of inhaled NPs by diffusion vs. additional deposition by sedimentation and impaction for micron-sized particles.ConclusionAgNPs following acute inhalation by rats are evenly retained in each lung lobe in terms of mass per unit lung tissue weight. Accordingly, we suggest sampling any of the rat lung lobes for lung burden analysis can be used to determine deposited or retained total lung burden after short-term inhalation of NPs and using the other lobes for collecting and analyzing bronchoalveolar lavage fluid (BALF) and for histopathological analysis. Therefore, by combining lung burden measurement, histopathological tissue preparation, and BALF assay in the same rat will reduce the number of animals used and maximize the number of endpoints measured.en_US
dc.description.sponsorshipThis research was supported by the Industrial Technology Innovation Program (10052901), Development of highly usable nanomaterial inhalation toxicity testing system in commerce through the Korea Evaluation Institute of Industrial Technology by the Korean Ministry of Trade, Industry & Energy and NIH/NIEHS grants U19ES019545, P30ES007033 and EPA grant RD83573801.en_US
dc.language.isoen_USen_US
dc.publisherBMCen_US
dc.subjectPARTICLEen_US
dc.subjectMONODISPERSEen_US
dc.subjectAEROSOLSen_US
dc.subjectRELEASEen_US
dc.titleLobar evenness of deposition/retention in rat lungs of inhaled silver nanoparticles: an approach for reducing animal use while maximizing endpointsen_US
dc.typeArticleen_US
dc.relation.volume16-
dc.identifier.doi10.1186/s12989-018-0286-9-
dc.relation.page1-10-
dc.relation.journalPARTICLE AND FIBRE TOXICOLOGY-
dc.contributor.googleauthorPark, Jung Duck-
dc.contributor.googleauthorKim, Jin Kwon-
dc.contributor.googleauthorJo, Mi Seong-
dc.contributor.googleauthorKim, Young Hun-
dc.contributor.googleauthorJeon, Ki Soo-
dc.contributor.googleauthorLee, Ji Hyun-
dc.contributor.googleauthorFaustman, Elaine M.-
dc.contributor.googleauthorLee, Hong Ku-
dc.contributor.googleauthorAhn, Kangho-
dc.contributor.googleauthorGulumian, Mary-
dc.contributor.googleauthorOberdorster, Gunter-
dc.contributor.googleauthorYu, Il Je-
dc.relation.code2019003246-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentDEPARTMENT OF MECHANICAL ENGINEERING-
dc.identifier.pidkhahn-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE