329 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정윤선-
dc.date.accessioned2019-12-10T01:27:51Z-
dc.date.available2019-12-10T01:27:51Z-
dc.date.issued2018-11-
dc.identifier.citationJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, v. 19, no. 6, page. 193-199en_US
dc.identifier.issn1526-9914-
dc.identifier.urihttps://aapm.onlinelibrary.wiley.com/doi/full/10.1002/acm2.12480-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/120582-
dc.description.abstractPurpose The delivery quality assurance (DQA) of intensity-modulated radiotherapy (IMRT) plans is a prerequisite for ensuring patient treatments. This work investigated the clinical usefulness of a new DQA system, Dosimetry Check (TM)(DC), on TomoTherapy((R))-based helical IMRT plans. Methods The DQA was performed for 15 different TomoTherapy((R))-based clinical treatment plans. In Tomotherapy((R)) machines, the couch position was set to a height of 400 mm and the treatment plans were delivered using QA-Treatment mode. For each treatment plan, the plan data and measured beam fluence were transferred to a DC-installed computer. Then, DC reconstructed the three-dimensional (3D) dose distribution to the CT images of the patient. The reconstructed dose distribution was compared with that of the original plan in terms of absolute dose, two-dimensional (2D) planes and 3D volume. The DQA results were compared with those performed by a conventional method using the cheese phantom with ion chamber and radiochromic film.Results For 14 out of the 15 treatment plans, the absolute dose difference between the measurement and calculation was less than 3% and the gamma pass rate with the 3%/3 mm gamma evaluation criteria was greater than 95% for both DQA methods. The P-value calculated using Wilcoxon signed-rank test was 0.256, which implies no statistically significance in determining the absolute dose difference between the two methods. For one treatment plan generated using the 5.0 cm field width, the absolute dose difference was greater than 3% and the gamma pass rate was less than 95% with DC, while the DQA result with the cheese phantom method passed our TomoTherapy((R)) DQA tolerance. Conclusion We have clinically implemented DC for the DQA of TomoTherapy((R))-based helical IMRT treatment plans. DC carried out the accurate DQA results as performed with the conventional cheese phantom method. This new DQA system provided more information in verifying the dose delivery to patients, while simplifying the DQA process.en_US
dc.description.sponsorshipThis work was supported in part by Basic Science Research Program through the National Research Foundation of Korea (KRF) funded by the Ministry of Education (No. 2015R1D1A1A01059833).en_US
dc.language.isoen_USen_US
dc.publisherWILEYen_US
dc.subjectdelivery quality assurance (DQA)en_US
dc.subjectDosimetry Check (TM)en_US
dc.subjectpretreatment verificationen_US
dc.subjectTomoTherapy((R))en_US
dc.titleClinical implementation of Dosimetry Check (TM) for TomoTherapy((R)) delivery quality assuranceen_US
dc.typeArticleen_US
dc.relation.no6-
dc.relation.volume19-
dc.identifier.doi10.1002/acm2.12480-
dc.relation.page193-199-
dc.relation.journalJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS-
dc.contributor.googleauthorChung, Eunah-
dc.contributor.googleauthorKwon, Dongyeol-
dc.contributor.googleauthorPark, Taeyang-
dc.contributor.googleauthorKang, Hyeri-
dc.contributor.googleauthorChung, Yoonsun-
dc.relation.code2018006040-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidychung-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE