316 150

Full metadata record

DC FieldValueLanguage
dc.contributor.author김용균-
dc.date.accessioned2019-12-06T07:28:21Z-
dc.date.available2019-12-06T07:28:21Z-
dc.date.issued2018-03-
dc.identifier.citationPLOS ONE, v. 13, no. 3, Article no. e0193809en_US
dc.identifier.issn1932-6203-
dc.identifier.urihttps://journals.plos.org/plosone/article?id=10.1371/journal.pone.0193809-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/117984-
dc.description.abstractImage co-registration is used in frameless gamma knife radiosurgery (GKSRS) to assign a stereotactic coordinate system and verify patient setup before irradiation. The accuracy of co-registration with cone beam computed tomography (CBCT) images of a Gamma Knife Icon TM (GK Icon) was assessed, and the effects of the region of co-registration (ROC) were studied. CBCT-to-CBCT co-registration is used for patient setup verification, and its accuracy was examined by co-registering CBCT images taken at various configurations with a reference CBCT series. The accuracy of stereotactic coordinate assignment was investigated by co-registering stereotactic CT images with CBCT images taken at various configurations. An anthropomorphic phantom was used, and the coordinates of fifteen landmarks inside the phantom were measured. The co-registration accuracy between stereotactic magnetic resonance (MR) and CBCT images was evaluated using images from forty-one patients. The positions of the anterior and posterior commissures were measured in both a fiducial marker-based system and a co-registered system. To assess the effects of MR image distortions, co-registration was performed with four different ranges, and the accuracy of the results was compared. Co-registration between CBCT images gave a mean three-dimensional deviation of 0.2 +/- 0.1 mm. The co-registration of stereotactic CT images with CBCT images produced a mean deviation of 0.5 +/- 0.2 mm. The co-registration of MR images with CBCT images resulted in the smallest three-dimensional difference (0.8 +/- 0.3 mm) when a co-registration region covering the skull base area was applied. The image co-registration errors in frameless GKSRS were similar to the imaging errors of frame-based GKSRS. The lower portion of the patient's head, including the base of the skull, is recommended for the ROC.en_US
dc.description.sponsorshipThis study was supported by grant no. NRF-2015M2A2A4A02044802 from National Research Foundation of Korea (www.nrf,re.kr) (HTC) and grant no. 10069168 from Korea Evaluation Institute of Industrial Technology (www.keit.re.kr) (KJC). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.en_US
dc.language.isoen_USen_US
dc.publisherPUBLIC LIBRARY SCIENCEen_US
dc.subjectCOMPUTED-TOMOGRAPHYen_US
dc.subjectRADIOSURGERYen_US
dc.titleAssessment of image co-registration accuracy for frameless gamma knife surgeryen_US
dc.typeArticleen_US
dc.relation.no3-
dc.relation.volume13-
dc.identifier.doi10.1371/journal.pone.0193809-
dc.relation.page1-16-
dc.relation.journalPLOS ONE-
dc.contributor.googleauthorChung, Hyun-Tai-
dc.contributor.googleauthorKim, Jeong Hun-
dc.contributor.googleauthorKim, Jin Wook-
dc.contributor.googleauthorPaek, Sun Ha-
dc.contributor.googleauthorKim, Dong Gyu-
dc.contributor.googleauthorChun, Kook Jin-
dc.contributor.googleauthorKim, Tae Hoon-
dc.contributor.googleauthorKim, Yong Kyun-
dc.relation.code2018006288-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidykkim4-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE