dc.description.abstractThe main purpose of this research is to suggest a virtual water flowmeter applicable in hydraulic systems with low-cost sensors. Practical procedures for realizing virtual water flowmeters for constant flow pumps (i.e., Cases 1 and 2) and variable flow pumps (i.e., Cases 3 and 4) are proposed in this paper. In Case 1, for measuring the water flow rate through a constant flow pump, the pump head was measured and the water flow rate was estimated using the pump characteristic curve obtained from the manufacturer or by deriving an empirical model based on the field measurement data. In Case 2, the water flow rate through a valve with a constant flow pump was estimated by measuring the pressure head between the valve and the valve opening position. The valve characteristic curve can be obtained by deriving an empirical model based on the initial field test results. The water flow rate through the variable flow pump was calculated, using the pump affinity laws and an empirical model, by measuring the frequency (i.e., Case 3) or input power (i.e., Case 4). The initial setup and test procedures for virtual flowmeters are also proposed in this research for practical use in the field. To verify the proposed procedures, experiments were conducted using constant and variable flow pumps in a pilot system. It was found that the virtual water flowmeters showed 2.9% to 6.7% of root mean square error from Case 1 to Case 4, compared with an ultrasonic water flowmeter, through long-term experimental verification. (C) 2017 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipThis work was supported by grants from the National Research Foundation (NRF) of Korea (No. 2015R1A2A1A05001726, and No. 2015M3D2A1032742) and the Korea Agency for Infrastructure Technology Advancement (KAIA) (17CTAP-C116268-02).en_US
dc.language.isoen_USen_US
dc.publisherELSEVIER SCIENCE SAen_US
dc.subjectVirtual flowmeteren_US
dc.subjectPump flow rate measurementen_US
dc.subjectInitial test procedureen_US
dc.subjectExperimental verificationen_US
dc.titleExperimental verification of a virtual water flowmeter applicable to air conditioning systemsen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume155-
dc.identifier.doi10.1016/j.enbuild.2017.09.050-
dc.relation.page425-438-
dc.relation.journalENERGY AND BUILDINGS-
dc.contributor.googleauthorKim, Min-Hwi-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.relation.code2017007385-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE