266 0

Experimental study on airtightness test methods in large buildings

Title
Experimental study on airtightness test methods in large buildings
Author
정재원
Keywords
Airtightness; Large building; Pressurization test; Pressure difference; Standard; Field test
Issue Date
2017-09
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Citation
BUILDING AND ENVIRONMENT, v. 122, page. 61-71
Abstract
Airtightness measurement standards using the fan pressurization method are widely used for measuring residential units such as detached houses and apartment units. The measurement of airtightness for small buildings can be readily conducted through existing fan pressurization methods. However, it can be difficult to achieve accurate measurement results for large buildings, as the height and volume of the buildings are considerably increased. This paper empirically investigates factors that are to be considered in regard to airflow rate (Q) and pressure difference (Delta P), which are measurement values required for deriving more accurate airtightness values for large buildings. The specifications of the standards ISO 9972, EN 13829, ASTM E779, JIS A 2201, ATTMA TS 1, and CAN/CGSB 149.15 relating to Q. and Delta P are compared. Test conditions with respect to Q and Delta P are discussed for large building airtightness measurements. In measuring airtightness, a method is proposed in which the pressure difference at each floor of the building is measured and an average pressure difference value is used. Experiments were conducted on two multi-story office buildings using the method based on measuring pressure difference according to existing standards in tandem with the proposed pressure difference measurement method. The results of the experimental study show that the vertical pressure distribution across the overall building envelope can be significantly different when a building is pressurized. The airtightness values may also be different according to the measurement methods. This paper demonstrates how important it is to derive accurate Delta P values in measuring large building airtightness. (C) 2017 Elsevier Ltd. All rights reserved.
URI
https://www.sciencedirect.com/science/article/pii/S0360132317302305?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/115690
ISSN
0360-1323; 1873-684X
DOI
10.1016/j.buildenv.2017.06.003
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE