Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 오재훈 | - |
dc.date.accessioned | 2019-11-26T20:33:46Z | - |
dc.date.available | 2019-11-26T20:33:46Z | - |
dc.date.issued | 2017-07 | - |
dc.identifier.citation | 의공학회지, v. 38, no. 3, page. 111-115 | en_US |
dc.identifier.issn | 1229-0807 | - |
dc.identifier.uri | http://koreascience.or.kr/article/JAKO201720861273578.page | - |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/114832 | - |
dc.description.abstract | Blood pressure is one of the important vital signs for monitoring the medical condition of a patient. Automated NIBP(non-invasive blood pressure) monitoring devices calculate systolic and diastolic blood pressures from the oscillation in cuff pressure caused by a pulsation of an artery. To validate the NIBP devices, we developed a simulator to supply the oscillometric waveforms obtained from human subjects. The simulator provided pressure pulses to device-under-test and device readings were compared to the auscultatory references. Fully automated simulation system including OCR(optical character recognition) were developed and used for NIBP monitoring devices. The validation results using the simulator agreed well with previous clinical validation. More validation studies using the standardized oscillometric waveforms would be required for the replacement of clinical trials to validate a new automated NIBP monitoring device. | en_US |
dc.description.sponsorship | This work was supported by the Korea Research Institute of Standards and Science under the project "Establishment of measurement standards for medical metrology", grant 17011038. | en_US |
dc.language.iso | ko_KR | en_US |
dc.publisher | 대한의용생체공학회 | en_US |
dc.subject | Non-invasive blood pressure(NIBP) | en_US |
dc.subject | Simulator | en_US |
dc.subject | Oscillometric waveform | en_US |
dc.subject | Clinical validation | en_US |
dc.subject | Pressure Pulse | en_US |
dc.title | 자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발 | en_US |
dc.title.alternative | A Simulator for the Validation of Non-invasive Blood Pressure(NIBP) Monitoring Devices | en_US |
dc.type | Article | en_US |
dc.relation.no | 3 | - |
dc.relation.volume | 38 | - |
dc.identifier.doi | 10.9718/JBER.2017.38.3.111 | - |
dc.relation.page | 111-115 | - |
dc.relation.journal | 의공학회지 | - |
dc.contributor.googleauthor | 도일 | - |
dc.contributor.googleauthor | 임현균 | - |
dc.contributor.googleauthor | 안봉영 | - |
dc.contributor.googleauthor | 지영준 | - |
dc.contributor.googleauthor | 이종실 | - |
dc.contributor.googleauthor | 오재훈 | - |
dc.contributor.googleauthor | Doh, Il | - |
dc.contributor.googleauthor | Lim, Hyun Kyoon | - |
dc.contributor.googleauthor | Ahn, Bongyoung | - |
dc.contributor.googleauthor | Chee, Youngjoon | - |
dc.contributor.googleauthor | Lee, Jongshill | - |
dc.contributor.googleauthor | OH, Jae Hoon | - |
dc.relation.code | 2017019208 | - |
dc.sector.campus | S | - |
dc.sector.daehak | COLLEGE OF MEDICINE[S] | - |
dc.sector.department | DEPARTMENT OF MEDICINE | - |
dc.identifier.pid | ojjai | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.