368 0

Impulse oscillometry and spirometry exhibit different features of lung function in bronchodilation

Title
Impulse oscillometry and spirometry exhibit different features of lung function in bronchodilation
Author
이경석
Keywords
Asthma; bronchodilator response test (BDR test); impulse oscillometry system (IOS); spirometry
Issue Date
2018-12
Publisher
TAYLOR & FRANCIS LTD
Citation
JOURNAL OF ASTHMA, v. 55, NO 12, Page. 1343-1351
Abstract
Objective: Bronchodilator responses (BDRs) from impulse oscillometry (IOS) are not interchangeable with those from spirometry. We aimed to identify the characteristics of children with small airway hyperresponsiveness and to determine whether BDR from IOS provides an important supplement to BDR from spirometry. Methods: The records of 592 children with asthma or suspected asthma who underwent spirometric and oscillometric BDRs were retrospectively reviewed. Oscillometric BDR was defined as positive when relative or absolute changes of Rrs(5) or Xrs(5) were beyond two standard deviations and spirometric BDR as positive when absolute change of forced expiratory volume in one second (FEV1) was >= 12%. Subjects were classified as positive for spirometric BDR only, positive for oscillometric BDR only, positive for both BDRs, or negative for both BDRs. Results: The results indicated that 101 (17.6%) subjects were positive for spirometric BDR only, 49 (8.5%) positive for oscillometric BDR only, 48 (8.3%) positive for both BDRs, and 377 (65.6%) negative for both BDRs. The agreement between spirometric and oscillometric BDRs was poor. Baseline FEV1, Rrs(5), and Xrs(5) values strongly influenced the BDRs. Subjects positive for oscillometric BDR only were found to be younger than those positive for spirometric BDR only (P < 0.001). Subjects positive for both BDRs were more likely to have asthma, atopic dermatitis, wheezing apart from cold, or decreased baseline lung function relative to those positive in either test (P < 0.001). Conclusions: There was a low concordance between spirometric and oscillometric BDRs. Use of IOS to detect small airway hyperresponsiveness may add more information about a clinical profile of subjects with asthma.
URI
https://www.tandfonline.com/doi/full/10.1080/02770903.2017.1418884https://repository.hanyang.ac.kr/handle/20.500.11754/108152
ISSN
0277-0903; 1532-4303
DOI
10.1080/02770903.2017.1418884
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE