257 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author윤준용-
dc.date.accessioned2019-07-09T07:34:30Z-
dc.date.available2019-07-09T07:34:30Z-
dc.date.issued2007-11-
dc.identifier.citation유체기계공업학회 2007 유체기계 연구개발 발표회 논문집, Page. 97 - 102en_US
dc.identifier.urihttp://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01002260&language=ko_KR-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/107231-
dc.description.abstractThis study carried out the safety evaluation of gas cylinder for portable gas range equipped with relief valve for prevention of explosion. The gas cylinder is heated by electric heater at the real using condition and the extreme condition after installing at the portable gas range for checking the operating pressure and evaluating the suitability of releasing flux. And the possibility of fire or explosion was released from the relief valve at the real using condition.en_US
dc.language.isoko_KRen_US
dc.publisher한국유체기계학회en_US
dc.subjectSafety evaluation(안전성 평가)en_US
dc.subjectPortable gas range(휴대용 부탄 연소기)en_US
dc.subjectRelief valve(안전밸브)en_US
dc.subjectLower explosion limit(폭발한계범위)en_US
dc.title릴리프 밸브를 장착한 이동식 부탄연소기용 부탄캔의 분출가스 확산 해석en_US
dc.title.alternativePrediction on Diffusion of Released Gas from Butane Can installed Relief Valve for Prevention of Explosionen_US
dc.typeArticleen_US
dc.contributor.googleauthor강승규-
dc.contributor.googleauthor최경석-
dc.contributor.googleauthor윤준용-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentDEPARTMENT OF MECHANICAL ENGINEERING-
dc.identifier.pidjoyoon-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MECHANICAL ENGINEERING(기계공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE