Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 송규동 | - |
dc.date.accessioned | 2019-05-17T01:05:47Z | - |
dc.date.available | 2019-05-17T01:05:47Z | - |
dc.date.issued | 2008-04 | - |
dc.identifier.citation | 한국건축친환경설비학회 2008년 춘계학술발표대회 논문집, Page. 104-109 | en_US |
dc.identifier.uri | http://www.dbpia.co.kr/Journal/ArticleDetail/NODE01212275 | - |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/104470 | - |
dc.description.abstract | This study presents a computer-aided visualization of the influence of reflected sunlight from glass curtain wall buildings. A reflection glare area is proposed as a performance index in the evaluation of reflection glare. A reflection glare area is conducted through the computer simulation of a 1 × 1 × 1 test model with four facades made by reflective material. The model is used to reference the horizontal area that would receive reflection in order to provide the comparison base of evaluation. A reflection glare area is smaller at the summer solstice than at the spring or autumnal equinox. The reflection glare area is compared at different angles of orientation of walls and different ratio of the width, the length and the height. In order to reduce reflection glare area, a passive design approach was applied by rotating plans to evaluate how the orientation of the facade would affect reflected glare. The simulation enabled design evaluation, with an inspection above normal eye level and in a broader area, than that which normally could be achieved in a site survey at a pedestrain's or a driver's level. The computer simulation verified the influence of reflection on the urban environment by using a time-based record. | en_US |
dc.language.iso | ko_KR | en_US |
dc.publisher | 한국건축친환경설비학회 | en_US |
dc.subject | 눈부심 | en_US |
dc.subject | 반사 | en_US |
dc.subject | 커튼월 | en_US |
dc.subject | Glare | en_US |
dc.subject | Reflection | en_US |
dc.subject | Curtain wall | en_US |
dc.title | 고반사 커튼월 건물의 직사일광 반사영역 산정 | en_US |
dc.title.alternative | Estimating Direct Sunlight Reflection Area of High-reflectance Curtain Wall Buildings | en_US |
dc.type | Article | en_US |
dc.contributor.googleauthor | 이종영 | - |
dc.contributor.googleauthor | 김지현 | - |
dc.contributor.googleauthor | 송규동 | - |
dc.sector.campus | E | - |
dc.sector.daehak | COLLEGE OF ENGINEERING SCIENCES[E] | - |
dc.sector.department | DIVISION OF ARCHITECTURE | - |
dc.identifier.pid | kdsong | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.