437 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author문영식-
dc.date.accessioned2019-05-03T00:42:36Z-
dc.date.available2019-05-03T00:42:36Z-
dc.date.issued2017-04-
dc.identifier.citationIEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, v. E100D, No. 4, Page. 901-909en_US
dc.identifier.issn1745-1361-
dc.identifier.urihttps://www.jstage.jst.go.jp/article/transinf/E100.D/4/E100.D_2016EDP7419/_article/-char/ja/-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/103254-
dc.description.abstractPrecise estimation of coronary arteries from computed tomography angiography (CTA) data is one of the challenging problems. This study focuses on automatic delineation of coronary arteries from 3D CTA data that may assess the clinicians in identifying the coronary pathologies. In this work, we present a technique that effectively segments the complete coronary arterial tree under the guidance of initial vesselness response without relying on heavily manual operations. The proposed method isolates the coronary arteries with accuracy by using localized statistical energy model in two directions provided with an automated seed which ensures an optimal segmentation of the coronaries. The detection of seed is carried out by analyzing the shape information of the coronary arteries in three successive cross-sections. To demonstrate the efficiency of the proposed algorithm, the obtained results are compared with the reference data provided by Rotterdam framework for lumen segmentation and the level-set active contour based method proposed by Lankton et al. Results reveal that the proposed method performs better in terms of leakages and accuracy in completeness of the coronary arterial tree.en_US
dc.language.isoen_USen_US
dc.publisherIEICE-INST ELECTRONICS INFORMATION COMMUNICATIONS ENGen_US
dc.subjectsegmentationen_US
dc.subjectcomputed tomography angiographyen_US
dc.subjectcoronary arteryen_US
dc.subjecttwo-way active contouren_US
dc.subjectvesselness responseen_US
dc.subjectSTENOSIS QUANTIFICATIONen_US
dc.subjectIMAGE SEGMENTATIONen_US
dc.subjectANGIOGRAPHYen_US
dc.titleAutomatic and Effective Delineation of Coronary Arteries from CTA Data Using Two-Way Active Contour Modelen_US
dc.typeArticleen_US
dc.relation.no4-
dc.relation.volumeE100D-
dc.identifier.doi10.1587/transinf.2016EDP7419-
dc.relation.page901-909-
dc.relation.journalIEICE TRANSACTIONS ON INFORMATION AND SYSTEMS-
dc.contributor.googleauthorZai, Sammer-
dc.contributor.googleauthorAnsari, Muhammad Ahsan-
dc.contributor.googleauthorMoon, Young Shik-
dc.relation.code2017004116-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF COMPUTING[E]-
dc.sector.departmentDIVISION OF COMPUTER SCIENCE-
dc.identifier.pidysmoon-
Appears in Collections:
COLLEGE OF COMPUTING[E](소프트웨어융합대학) > COMPUTER SCIENCE(소프트웨어학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE