215 0

벽걸이에어컨의 원심홴에 대한 과도진동 규명 및 저감

Title
벽걸이에어컨의 원심홴에 대한 과도진동 규명 및 저감
Other Titles
Transient Vibration Identification and Reduction of a Centrifugal Fan for a Wall-installed Air-conditioner
Author
정진태
Keywords
Centrifugal Fan; 원심홴; Vibration; 진동
Issue Date
2016-08
Publisher
한국소음진동공학회
Citation
한국소음진동공학회논문집, v. 26, No. 4, Page. 383-390
Abstract
In this paper, experiment and dynamics simulations were carried out to identify and reduce the out-of-plane vibration that occurs in a centrifugal fan of an air conditioner installed to a wall. In a wall-installed air conditioner, large space between a case and heat exchanger is often required for the fan to avoid the collision with the case and exchanger. This large space hinders the slim design of the air conditioner even if air conditioner market demands a slim air conditioner. In the present study, in order to determine the cause of the vibration in the centrifugal fan, the out-of-plane vibration and the physical properties were investigated, and the dynamic characteristics of the centrifugal fan were obtained by experiments. Based on these experiments, a dynamic simulation model was established to determine the cause of the out-of-plane vibration of the centrifugal fan. It was found that the main factor of out-of-lane vibration in the centrifugal fan is the axial misalignment between the centrifugal fan and the motor shaft.
URI
http://www.dbpia.co.kr/Journal/ArticleDetail/NODE06762755https://repository.hanyang.ac.kr/handle/20.500.11754/102678
ISSN
1598-2785
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MECHANICAL ENGINEERING(기계공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE