저온환경하 콘크리트 시공을 위한 영하온도 경화가능형 시멘트 모르타르 및 단열·발열거푸집 개발에 관한 실험적 연구

Title
저온환경하 콘크리트 시공을 위한 영하온도 경화가능형 시멘트 모르타르 및 단열·발열거푸집 개발에 관한 실험적 연구
Other Titles
An Experimental Study on Below Zero Temperature Curable Cement Mortar and Insulated · Heating Forms Development for Concrete Casting at Low Temperature
Author
이한승
Keywords
저온환경; 방동제; 내한촉진제; 단열거푸집; 발열거푸집; Low Temperature; Anti-freeze Agent; Accelerator for Freeze Protection; Insulated Form; Heating Form
Issue Date
2016-05
Publisher
대한건축학회
Citation
대한건축학회논문집 - 구조계, v. 32, No. 5, Page. 11-18
Abstract
Domestic construction market is congested enough at the moment cause enterprises to enter overseas market such as Mongolia and Russia. However most previous studies conducted at a temperature above freezing. In this study, performance analysis of cement mortar was conducted without extra heating air supplying at a low temperature below freezing. For this study, all of materials for experiment were kept in a low temperature for 48 hours before mortar mixing. After mortar curing at low temperature, compressive strength was measured at the early ages. Also, properties of hardened cement material was analysed using TG-DTA and MIP. At experiment series 1, to figure out whether cement hydration reaction at low temperature below freezing is possible or not, use anti-freezing agent to protect freezing of water used in mortar mixture and analyze increasing amount of Ca(OH)2, chemical bound water contained in mortar by usage of hardening accelerator and curing period at low temperature condition. At experiment series 2, insulated and heating form have been used with mortar has same mix proportion as series 1. Thermal performance and compressive strength of mortar are conducted and analyzed excremental result according to the variable form types. Especially, high fineness cement is considered to use with insulated form. Hydration heat of quicklime is used for heating form in this study. The analysis of this study confirmed that high fineness cement with insulated form and heating form can be suitable to be used in low temperature environment.
URI
http://www.dbpia.co.kr/Journal/ArticleDetail/NODE06682197https://repository.hanyang.ac.kr/handle/20.500.11754/102434
ISSN
1226-9107
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ARCHITECTURE(건축학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE