195 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author손주현-
dc.date.accessioned2019-04-19T02:20:10Z-
dc.date.available2019-04-19T02:20:10Z-
dc.date.issued2016-12-
dc.identifier.citationULTRASONICS, v. 72, Page. 158-164en_US
dc.identifier.issn0041-624X-
dc.identifier.issn1874-9968-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0041624X1630138X?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/102357-
dc.description.abstractThe purpose of this study is to evaluate whether a 5-repetition liver stiffness (LS) measurement as the standard protocol of shear wave elastography (SWE) is comparable to a conventional 10-repetition measurement protocol and to identify factors that influence the reliability of the 5-repetition protocol. A total of 346 patients (mean, 48.0 years; range, 15-81 years, M:F = 192:154) who underwent SWE were enrolled. The median, first quartile, third quartile, and interquartile range divided by the median (IQR/M) of LS measurement were calculated and compared between 5-repetition and 10-repetition protocols. Subgroup analyses were also performed to identify factors associated with measurement reliability. The overall mean LS from the 10-repetition protocol was 7.97 kPa, which was not significantly different from the mean LS of the 5-repetition protocol (7.91 kPa; p = 0.192). However, the third quartile and IQR/M values of the two groups were significantly different from each other (p = 0.003 and <0.001). Subgroup analysis revealed that the 5-repetition results were significantly different from the 10-repetition results in the fatty liver and high LS subgroups. Therefore, the 5-repetition SWE measurement protocol can replace the conventional 10-repetition protocol, with the exception of patients with fatty liver disease or an LS value higher than 10 kPa. (C) 2016 Elsevier B.V. All rights reserved.en_US
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE BVen_US
dc.subjectDiffuse liver diseaseen_US
dc.subjectShear wave elastographyen_US
dc.subjectLiver stiffness measurementen_US
dc.subjectIntra-observer variationen_US
dc.titleHow many times should we repeat measuring liver stiffness using shear wave elastography?: 5-repetition versus 10-repetition protocols.en_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.ultras.2016.08.005-
dc.relation.page158-164-
dc.relation.journalULTRASONICS-
dc.contributor.googleauthorChoi, Seung Hee-
dc.contributor.googleauthorJeong, Woo Kyoung-
dc.contributor.googleauthorKim, Yongsoo-
dc.contributor.googleauthorLim, Sanghyeok-
dc.contributor.googleauthorKwon, Jong Won-
dc.contributor.googleauthorKim, Tae Yeob-
dc.contributor.googleauthorKim, Min Yeong-
dc.contributor.googleauthorSohn, Joo Hyun-
dc.relation.code2016000974-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidsonjh-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE