230 0

기존 공동 주택의 에너지 성능 진단을 위한 U-value 현장 측정 및 평가

Title
기존 공동 주택의 에너지 성능 진단을 위한 U-value 현장 측정 및 평가
Other Titles
U-value in situ measurement & assesment for energy performance diagnosis of existing apartment building
Author
송규동
Keywords
벽체 열성능; 기존 공동 주택; 열류계; 에너지진단; Wall thermal performance; Existing apartment building; Heat Flux meter; Energy diagnosis
Issue Date
2016-03
Publisher
한국태양에너지학회
Citation
한국태양에너지학회 2016년도 춘계학술발표대회 논문초록집, Page. 31-31
Abstract
Energy performance diagnosis of existing apartment buildings are becoming important for achieving energy saving. Nowadays, also in situ measurement of U-value using heat flow meters are available. In this paper, present the results of an experimental campaign to assess the wall thermal performance by HFMs. Furthermore, in situ U-values have been compared with the estimated ones from design data and field analyses. The results of the test show a good behavior of HFMs when tests are conducted according to ISO 9869. The paper presents the results of a measurement campaign of in situ thermal transmittance, performed in some buildings in the Seoul region designed implementing ‘Home Energy Efficiency Improvement Project’ solutions.
URI
http://www.dbpia.co.kr/Journal/ArticleDetail/NODE06671974https://repository.hanyang.ac.kr/handle/20.500.11754/102188