Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 태성호 | - |
dc.date.accessioned | 2019-02-20T01:37:30Z | - |
dc.date.available | 2019-02-20T01:37:30Z | - |
dc.date.issued | 2018-04 | - |
dc.identifier.citation | 대한건축학회 2018년도 춘계학술발표대회논문집, v. 38, No. 1, Page. 426-429 | en_US |
dc.identifier.issn | 2287-5786 | - |
dc.identifier.uri | http://www.dbpia.co.kr/Journal/ArticleDetail/NODE07462918# | - |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/99088 | - |
dc.description.abstract | This study compared recently developed domestic electrochromic glazing with the double glazing and shading devices commercialized for office buildings in Korea for load reduction performance evaluation. This study proposed a hypothesis that the load reduction performance of electrochromic glazing with variable solar control and high solar radiation rejection would be higher than that of existing double glazing products and shading devices and analyzed the cooling and heating load of different types of double glazing. Bleached electrochromic glazing exhibited low transmittance compared to colored glass double glazing, low-e double glazing, and double glazing with a shading device. Colored electrochromic glazing provided higher solar radiation rejection compared to colored glass double glazing and low-e double glazing. Hence, it was effective for cooling load reduction. | en_US |
dc.language.iso | ko_KR | en_US |
dc.publisher | 대한건축학회 | en_US |
dc.subject | 전기변색유리 | en_US |
dc.subject | 광학특성 | en_US |
dc.subject | 냉난방부하 | en_US |
dc.subject | 사무소건물 | en_US |
dc.subject | 에너지플러스 | en_US |
dc.subject | Electrochromic | en_US |
dc.subject | Optical Property | en_US |
dc.subject | Heating and Cooling Load | en_US |
dc.subject | Office Building | en_US |
dc.subject | EnergyPlus | en_US |
dc.title | 전기변색유리의 광학특성 및 냉난방부하 분석을 통한 사무소건물 적용성 평가 | en_US |
dc.title.alternative | An Applicability Estimation of Electrochromic Glazing in the Office Building based on Analyzing Optical Properties and Heating and Cooling Load | en_US |
dc.type | Article | en_US |
dc.relation.no | 1 | - |
dc.relation.volume | 38 | - |
dc.relation.page | 426-429 | - |
dc.contributor.googleauthor | 오명환 | - |
dc.contributor.googleauthor | 태성호 | - |
dc.sector.campus | E | - |
dc.sector.daehak | COLLEGE OF ENGINEERING SCIENCES[E] | - |
dc.sector.department | DIVISION OF ARCHITECTURE | - |
dc.identifier.pid | jnb55 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.