483 270

Clinical Applicability of Newly Developed Image-based Cell Counter for Counting CD34+ Cells: Comparison with Flow Cytometric Analysis

Title
Clinical Applicability of Newly Developed Image-based Cell Counter for Counting CD34+ Cells: Comparison with Flow Cytometric Analysis
Other Titles
영상기반 세포수 측정기의 임상적 적용
Author
남은우
Keywords
Image-based cell counter; CD34+ cell
Issue Date
2016-10
Publisher
대한혈액종양학회
Citation
Clinical Pediatric Hematology-Oncology, v. 23, no. 2, Page. 125-132
Abstract
Background: Flow cytometric analysis is the standard method for enumerating CD34+ stem cells in hematopoietic stem cell transplantation. However, it has some limitations such as expensive instrumentation, high reagent costs, and discrepancies between technicians and laboratories. We compared counts of total nucleated cells (TNCs) and CD34+ cells counts obtained from a flow cytometer with a newly-developed image based microscopic cell counter (ADAM II) to evaluate the possibility of clinical application of the ADAM II.Methods: We used 18 samples of circulating peripheral blood (PB) and waste tube fractions of peripheral blood stem cells (PBSCs) harvested by apheresis after G-CSF mobilization from adult volunteer donors. We assessed the reproducibility and linearity of the new procedure and compared the numbers of TNCs and viable CD34+ cells determined with the ADAM II and two different flow cytometers (FACSCalibur, FACSCanto II).Results: Numbers of viable CD34+ cells determined with the ADAM II were accurate over the expected range; the intra-assay coefficient of variation was ≤19.8%. Linearity was also satisfactory (R2=0.99). TNC counts obtained with the ADAM II were highly correlated with those obtained with the FACSCalibur (R2>0.9841, P<0.0001) and FACSCanto II (R2>0.9620, P<0.0001), as were the numbers of viable CD34+ cells obtained with the ADAM II and the FACSCalibur and FACSCanto II (R2>0.9911, P<0.0001 and R2>0.9791, P<0.0001), respectively.Conclusion: The newly developed image-based microscopic cell counter (ADAM II) appears to be suitable for enumerating TNCs and viable CD34+ cells.
URI
http://www.cpho.or.kr/journal/view.html?vol=23&num=2&page=125&year=2016https://repository.hanyang.ac.kr/handle/20.500.11754/98835
ISSN
2233-5250; 2233-4580
DOI
10.15264/cpho.2016.23.2.125
Appears in Collections:
INDUSTRY-UNIVERSITY COOPERATION FOUNDATION[S](산학협력단) > ETC
Files in This Item:
Clinical Applicability of Newly Developed Image-based Cell Counter for Counting CD34+ Cells Comparison with Flow Cytometric Analysis.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE