243 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김성환-
dc.date.accessioned2018-09-13T01:05:26Z-
dc.date.available2018-09-13T01:05:26Z-
dc.date.issued2016-08-
dc.identifier.citationKNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, v. 24, no. 8, page 2710-2717en_US
dc.identifier.issn0942-2056-
dc.identifier.issn1433-7347-
dc.identifier.urihttps://link.springer.com/article/10.1007%2Fs00167-016-4011-7-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/75140-
dc.description.abstractLimited information is available regarding the effects of cementing extent on implant stability in patients who have undergone revision total knee arthroplasty (TKA). As such, the goals of this study were: (1) to determine the correlation between the extent of vertical cementing and implant loosening; (2) to determine whether the extent of cementing is a potential predictive factor for radiolucency; and (3) to evaluate the minimal amount of cement needed for a stable implant during revision TKA using a hybrid technique. One hundred nine stemmed/revision TKAs with a mean follow-up period of 5 years were retrospectively analysed. In each case, a single varus-valgus constrained implant was used and fixed with a hybrid technique. Implant stability was evaluated according to the modified Knee Society radiographic scoring system. The extent of vertical cementing was defined as the longitudinal length from the implant base to the end of the radiopaque line around the stem on radiograph. Its correlation with implant stability was analysed, and the minimal value for a stable implant was evaluated with a receiver operating characteristic (ROC) analysis. The mean extent of vertical cementing was longer in stable implants (femur: p = 0.001, tibia: p = 0.004) and significantly correlated with implant stability (femur: p < 0.001, tibia: p = 0.001). A logistic regression analysis revealed that the risk of loosening was 8.7-16.1 times higher when the extent of cementing was < 40 mm, which was located at the stem-implant junction of the modular implant. The minimal extent of vertical cementing was estimated to be 60 mm for a stable femoral implant and 50 mm for a tibial implant. The hybrid fixation technique with a cementing extent > 60 mm for the femur and 50 mm for the tibia was durable at a mean follow-up period of 5 years. Vertical cementing 10-20 mm above the stem-implant junction is recommended when performing revision TKA using this technique.en_US
dc.description.sponsorshipThe authors wish to thank Eun Mi Shin and Son Mi Ahn for supporting our research with collecting and organising the clinical data. We also appreciate statistical consultation provided by the Medical Research Collaborating Center at the Seoul National University College of Medicine/Seoul National University Hospital. This work was supported by the Ministry of Trade, Industry and Energy (MOTIE) Grant funded by the Korean government (No. 10045329). Grant was used for laboratory fees and salaries. The funding sources did not play a role in performing investigations for this study.en_US
dc.language.isoenen_US
dc.publisherSPRINGERen_US
dc.subjectRevision total knee arthroplastyen_US
dc.subjectCement extenten_US
dc.subjectHybrid fixationen_US
dc.subjectStemen_US
dc.titleExtent of vertical cementing as a predictive factor for radiolucency in revision total knee arthroplasty.en_US
dc.typeArticleen_US
dc.identifier.doi10.1007/s00167-016-4011-7-
dc.relation.journalKNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY-
dc.contributor.googleauthorRo, Du Hyun-
dc.contributor.googleauthorCho, Yool-
dc.contributor.googleauthorLee, Sahnghoon-
dc.contributor.googleauthorChung, Kee Yun-
dc.contributor.googleauthorKim, Seong Hwan-
dc.contributor.googleauthorLee, Young Min-
dc.contributor.googleauthorLee, Joon Kyu-
dc.contributor.googleauthorLee, Myung Chul-
dc.relation.code2016000413-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidksh170177-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE