An Active Feedforward Compensation for a Current Harmonics Reduction in Threephase Grid-connected Inverters
- Title
- An Active Feedforward Compensation for a Current Harmonics Reduction in Threephase Grid-connected Inverters
- Author
- 김래영
- Keywords
- Active feed forward; harmonic compensation; low frequency transformer; low order harmonic; THD; weak grid
- Issue Date
- 2013-11
- Publisher
- IEEE
- Citation
- IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society Industrial Electronics Society, IECON 2013 - 39th Annual Conference of the IEEE. :400-405 Nov, 2013
- Abstract
- The paper discusses the influence of a grid impedance, especially for a leakage inductance of a grid side transformer. The grid impedance does not usually take into account during the design stage of the current controller. As a result, low order harmonics in the grid current are distorted. In this paper, the active feed-forward compensation method is proposed for the purpose of attenuating the current distortion. The proposed method can be applied to L filter as well as LCL filter. The effectiveness of the method is verified through various simulations and experiments based on a 1.5kW voltage source inverter prototype
- URI
- http://ieeexplore.ieee.org/document/6699169/metricshttps://repository.hanyang.ac.kr/handle/20.500.11754/73257
- ISBN
- 978-1-4799-0224-8
- ISSN
- 1553-572X
- DOI
- 10.1109/IECON.2013.6699169
- Appears in Collections:
- COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
- Files in This Item:
There are no files associated with this item.