Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 조희윤 | - |
dc.date.accessioned | 2018-04-19T08:03:40Z | - |
dc.date.available | 2018-04-19T08:03:40Z | - |
dc.date.issued | 2012-06 | - |
dc.identifier.citation | 대한안과학회, 2012, 53(6),P.833-838. | en_US |
dc.identifier.issn | 0378-6471 | - |
dc.identifier.uri | http://scholar.dkyobobook.co.kr/searchDetail.laf?barcode=4010024354553 | - |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/69508 | - |
dc.description.abstract | Purpose: To compare axial length, anterior chamber depth, and keratometric measurements of an optical low-coherence reflectometry device with those of other ocular biometry devices and evaluate the accuracy of predicting postoperative refraction. Methods: A total of 32 eyes in 32 patients who received cataract surgery were included in the present study. The axial length, anterior chamber depth, and keratometry were measured by optical low-coherence reflectometry (Lenstar LS900?), partial coherence interferometry (IOL master?), and ultrasound. The SRK/T formula was used to calculate IOL power, and predictive error that subtracts predictive refraction from postoperative refraction was compared among ocular biometry devices. Results: Axial length, anterior chamber depth, and keratometry had a strong correlation and demonstrated no statistically significant differences between Lenstar LS900? and other devices. The Bland–Altman plots showed a high degree of agreement between Lenstar LS900? and other devices. The mean absolute prediction errors in Lenstar LS900? and IOL master? were not significantly different. Conclusions: The ocular biometric measurements and prediction of postoperative refraction using Lenstar LS900? were as accurate as IOL master? and ultrasound. J Korean Ophthalmol Soc 2012;53(6):833-838 | en_US |
dc.language.iso | ko_KR | en_US |
dc.publisher | 대한안과학회 | en_US |
dc.subject | Lenstar LS900 | en_US |
dc.subject | Ocular biometry | en_US |
dc.subject | Optical low coherence reflectometry | en_US |
dc.title | 저간섭성반사계와 부분결합간섭계를 이용한 안구생체계측과 백내장 수술 후 굴절력 예측의 비교 | en_US |
dc.title.alternative | Comparison of Ocular Biometry and Postoperative Refraction in Cataract Patients Between Lenstar? and IOL Master? | en_US |
dc.type | Article | en_US |
dc.relation.no | 6 | - |
dc.relation.volume | 53 | - |
dc.relation.page | 833-838 | - |
dc.relation.journal | 대한안과학회지 | - |
dc.contributor.googleauthor | 신중원 | - |
dc.contributor.googleauthor | 성민철 | - |
dc.contributor.googleauthor | 강민호 | - |
dc.contributor.googleauthor | 조희윤 | - |
dc.contributor.googleauthor | 이윤정 | - |
dc.relation.code | 2012216384 | - |
dc.sector.campus | S | - |
dc.sector.daehak | COLLEGE OF MEDICINE[S] | - |
dc.sector.department | DEPARTMENT OF MEDICINE | - |
dc.identifier.pid | hycho | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.