208 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정우경-
dc.date.accessioned2018-04-15T07:28:37Z-
dc.date.available2018-04-15T07:28:37Z-
dc.date.issued2011-05-
dc.identifier.citationJournal of ultrasound in medicine,Vol.30, No.5 [2011],635-642en_US
dc.identifier.issn0278-4297-
dc.identifier.urihttp://onlinelibrary.wiley.com/doi/abs/10.7863/jum.2011.30.5.635-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/66622-
dc.description.abstractObjectives- To compare time-enhancement curve parameters of contrast-enhanced sonography in acute partial hepatic venous outflow obstruction with those of a baseline study. Methods- Contrast-enhanced sonography was performed in 11 rabbits with bolus administration of a sulfur hexafluoride contrast agent (0.1 mL/kg). After baseline scanning for 3 minutes, a 5.3F balloon catheter was placed into the left hepatic vein. Obstruction was artificially induced by 0.4-mL balloon inflation, and sonography was repeatedly performed thereafter. On images stored with 1-second intervals, 2 × 2-mm regions of interest were placed, and mean luminosity was measured. Time-enhancement curves were plotted, and contrast arrival times, peak enhancement values, peak enhancement times, 50% wash-out times, and 3-minute wash-out rates were obtained. Paired t tests were performed to evaluate the significance of differences in the parameters between baseline and obstruction. Results- On baseline sonography, the median contrast arrival time, peak enhancement value, peak enhancement time, 50% wash-out time, and 3-minute wash-out rate were 6 (range, 4-8; mean ± SD, 5.9 ± 1.2) seconds, 188.5 (104.7-209.5; 178.4 ± 33.1) arbitrary units, 19 (14-27; 19.8 ± 4.1) seconds, 75 (60-101; 78.2 ± 13.9) seconds, and 89.7% (81.3%-95.1%; 88.4% ± 4.9%), respectively. With obstruction, those values were 7 (5-12; 6.9 ± 2.3) seconds, 202.8 (98.2-215.1; 186.0 ± 39.3) arbitrary units, 31 (17-59; 32 ± 11.6) seconds, 101 (47-136; 96.2 ± 23.6) seconds, and 79.2% (66.2%-88.8%; 79.1% ± 7.6%). Compared with baseline, the peak enhancement time was significantly delayed from 19 to 31 seconds (P = .0027), 50% wash-out time significantly delayed from 75 to 101 seconds (P = .0209), and 3-minute wash-out rate significantly decreased from 89.7% to 79.2% (Pen_US
dc.language.isoenen_US
dc.publisherAMERICAN INSTITUTE OF ULTRASOUND IN MEDICINEen_US
dc.subjectanimal studyen_US
dc.subjectcontrast-enhanced sonographyen_US
dc.subjecthepatic venous obstruc-tionen_US
dc.subjectperfusion studyen_US
dc.titleAcute Outflow Obstruction of Hepatic Veins in Rabbits Quantitative Analysis of Hepatic Perfusion With Contrast-Enhanced Sonographyen_US
dc.typeArticleen_US
dc.relation.no5-
dc.relation.volume30-
dc.identifier.doi10.7863/jum.2011.30.5.635-
dc.relation.page635-642-
dc.relation.journalJOURNAL OF ULTRASOUND IN MEDICINE-
dc.contributor.googleauthorJeong, Woo Kyoung-
dc.contributor.googleauthorKim, Kyoung Won-
dc.contributor.googleauthorKim, Pyo Nyun-
dc.contributor.googleauthorShin, Ji Hoon-
dc.contributor.googleauthorShin, Dong Ho-
dc.contributor.googleauthorWon, Hyung Jin-
dc.contributor.googleauthorShin, Yong Moon-
dc.contributor.googleauthorLee, Won Jae-
dc.contributor.googleauthorLee, Moon Gyu-
dc.contributor.googleauthorSong, Gi-Won-
dc.relation.code2011206088-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidjeongwk-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE