221 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김윤신-
dc.date.accessioned2018-04-15T07:22:35Z-
dc.date.available2018-04-15T07:22:35Z-
dc.date.issued2011-06-
dc.identifier.citationEnvironmental Science and Pollution Research, 2011, 18(5), P.743-755en_US
dc.identifier.issn0944-1344-
dc.identifier.urihttps://link.springer.com/article/10.1007%2Fs11356-010-0411-2-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/66609-
dc.description.abstractIntroductionThe purposes of this study, as part of research projects for establishing the preservation environment of domestic cultural properties, are to identify the hazardous environmental factors which have a possibility to cause damages on long-term preservation of cultural heritage within the museum exhibition halls and the storages area, and to provide the basic data for the future establishment of preservation environment.Materials and methodsThe temperature (23.5 and 20.6°C,) relative humidity (52.1% and 55.4%), PM10 (31.5 and 18.9 μg/m3), CO2 (472.7 and 526.8 ppm), HCHO (20.8 and 34.0 μg/m3), CO (0.3 and 0.3 ppm), NO2 (0.012 and 0.004 ppm), TVOCs (493.6 and 788.9 μg/m3), O3 (0.003 and 0.002 ppm), Rn (0.7 and 1.5 pCi/L), and SO2 (0.003 and 0.002 ppm) as chemical factors, and airborne bacteria and fungi as biological factors, were selected for this research subjects of hazardous environmental factors, which were the subjects of the study conducted by the National Research Institute of Cultural Heritage from 2006 to 2008, and the subjects of related domestic researches performed in fragments.Results and discussionThe concentration distributions of selected hazardous environmental factors in a museum environment were calculated by using the inverse variance weighted average in meta-analysis, and the concentration distributions possibly emerging in a museum exhibition halls and storages were computed through Monte Carlo simulation in order to minimize the uncertainty that can be caused from meagerness of related domestic researches.en_US
dc.language.isoenen_US
dc.publisherECOMED PUBLISHERSen_US
dc.subjectMuseumen_US
dc.subjectEnvironmental hazardousen_US
dc.subjectChemical factorsen_US
dc.subjectBiological factorsen_US
dc.titleCultural heritage: a potential pollution source in museumen_US
dc.typeArticleen_US
dc.relation.no5-
dc.relation.volume18-
dc.identifier.doi10.1007/s11356-010-0411-2-
dc.relation.page743-755-
dc.relation.journalENVIRONMENTAL MANAGEMENT-
dc.contributor.googleauthorLee, C.-
dc.contributor.googleauthorKim, Y.-
dc.contributor.googleauthorNagajyothi, P. C.-
dc.contributor.googleauthorThammalangsy, S.-
dc.contributor.googleauthorGoung, S. J.-
dc.relation.code2011202889-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidyoonshin-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE