247 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author류정아-
dc.date.accessioned2018-04-15T06:52:31Z-
dc.date.available2018-04-15T06:52:31Z-
dc.date.issued2011-06-
dc.identifier.citationKOREAN JOURNAL OF RADIOLOGY, JAN-FEB 2011, 12(1), p78-p88, 11p.en_US
dc.identifier.issn1229-6929-
dc.identifier.urihttps://synapse.koreamed.org/DOIx.php?id=10.3348/kjr.2011.12.1.78&vmode=FULL-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/66586-
dc.description.abstractObjective: We wanted to compare the two-dimensional (2D) fast spin echo (FSE) techniques and the three-dimensional (3D) fast fi eld echo techniques for the evaluation of the chondromalacia patella using a microscopy coil.Materials and Methods: Twenty five patients who underwent total knee arthroplasty were included in this study. Preoperative MRI evaluation of the patella was performed using a microscopy coil (47 mm). The proton density-weighted fast spin echo images (PD), the fat-suppressed PD images (FS-PD), the intermediate weighted-fat suppressed fast spin echo images (iw-FS-FSE), the 3D balanced-fast fi eld echo images (B-FFE), the 3D water selective cartilage scan (WATS-c) and the 3D water selective fl uid scan (WATS-f) were obtained on a 1.5T MRI scanner. The patellar cartilage was evaluated in nine areas: the superior, middle and the inferior portions that were subdivided into the medial, central and lateral facets in a total of 215 areas. Employing the Noyes grading system, the MRI grade 0-I, II and III lesions were compared using the gross and microscopic fi ndings. The sensitivity, specifi city and accuracy were evaluated for each sequence. The signifi cance of the differences for the individual sequences was calculated using the McNemar test.Results: The gross and microscopic findings demonstrated 167 grade 0-I lesions, 40 grade II lesions and eight grade III lesions. Iw-FS-FSE had the highest accuracy (sensitivity/specificity/accuracy = 88%/98%/96%), followed by FSPD (78%/98%/93%, respectively), PD (76%/98%/93%, respectively), B-FFE (71%/100%/93%, respectively), WATS-c (67%/100%/92%, respectively) and WATS-f (58%/99%/89%, respectively). There were statistically signifi cant differences for the iw-FS-FSE and WATS-f and for the PD-FS and WATS-f (p < 0.01).Conclusion: The iw-FS-FSE images obtained with a microscopy coil show best diagnostic performance among the 2D and 3D GRE images for evaluating the chondromalacia patella.en_US
dc.language.isoenen_US
dc.publisher대한영상의학회en_US
dc.subjectCartilageen_US
dc.subjectMagnetic resonance (MR)en_US
dc.subjectKneeen_US
dc.subjectHistopathologic correlationen_US
dc.titleEvaluation of the Chondromalacia Patella Using a Microscopy Coil: Comparison of the Two-Dimensional Fast Spin Echo Techniques and the Three-Dimensional Fast Field Echo Techniquesen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume12-
dc.identifier.doi10.3348/kjr.2011.12.1.78-
dc.relation.page78-88-
dc.relation.journalKOREAN JOURNAL OF RADIOLOGY-
dc.contributor.googleauthor김현주-
dc.contributor.googleauthor이상훈-
dc.contributor.googleauthor강창호-
dc.contributor.googleauthor류정아-
dc.contributor.googleauthor신명진-
dc.contributor.googleauthor조경자-
dc.contributor.googleauthor조우신-
dc.relation.code2011214265-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidryuja-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.