220 0

A systematic review of diagnostic accuracy of vertebral fracture assessment (VFA) in postmenopausal women and elderly men

Title
A systematic review of diagnostic accuracy of vertebral fracture assessment (VFA) in postmenopausal women and elderly men
Author
최윤영
Keywords
Osteoporosis; Systematic review; Vertebral fracture (VF); Vertebral fracture assessment (VFA)
Issue Date
2016-05
Publisher
SPRINGER LONDON LTD
Citation
OSTEOPOROSIS INTERNATIONAL, v. 27, NO 5, Page. 1691-1699
Abstract
This systematic review was performed to compare the diagnostic accuracy of vertebral fracture assessment (VFA) with that of spinal radiography for identification of vertebral fractures (VFs). VFA appeared to have moderate sensitivity and high specificity for detecting VFs when compared with spinal radiography. VFs are recognized as the hallmark of osteoporosis, and a previous VF increases the risk of a future fracture. Therefore, the timely detection of VFs is important for prevention of further fractures. This systematic review examined the diagnostic accuracy of VFA using dual X-ray absorptiometry (DXA) to identify VFs. We searched for potentially relevant studies using electronic databases, including Ovid-Medline, Ovid-EMBASE, Cochrane library, and four Korean databases, from their inception to May 2013. We compared the diagnostic accuracy of VFA with that of spinal radiography for detection of VFs by analyzing the sensitivity and specificity using a 2 x 2 contingency table. Subgroup analyses were also performed on studies with a low risk of bias and applicability. Twelve studies were analyzed for the diagnostic accuracy of VFA. The sensitivity and specificity were 0.70-0.93 and 0.95-1.00, respectively, analyzed on a per-vertebra basis, and 0.65-1.00 and 0.74-1.00 on a per-patient basis. The sensitivity and specificity of five studies in subgroups with a low risk of bias in the intervention test were 0.70-0.84 and 0.96-0.99, respectively. In studies with a low risk of bias in the patient selection, those based on a per-vertebra basis in three studies were 0.70-0.93 and 0.96-1.00, respectively. VFA had moderate sensitivity and high specificity for detecting VF when compared with spinal radiography. However, the present findings are insufficient to assess whether spinal radiography should be replaced by VFA.
URI
https://link.springer.com/article/10.1007%2Fs00198-015-3436-zhttp://hdl.handle.net/20.500.11754/65443
ISSN
0937-941X; 1433-2965
DOI
10.1007/s00198-015-3436-z
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE