316 0

T1-weighted Axial Visual Rating Scale for an Assessment of Medial Temporal Atrophy in Alzheimer's Disease

Title
T1-weighted Axial Visual Rating Scale for an Assessment of Medial Temporal Atrophy in Alzheimer's Disease
Author
이종민
Keywords
Alzheimer's disease; medial temporal atrophy; visual rating scale
Issue Date
2014-01
Publisher
IOS PRESS
Citation
JOURNAL OF ALZHEIMERS DISEASE, 2014, 41(1), p.169-178
Abstract
Background: The most-widely used visual rating scale (VRS) for medial temporal atrophy is the T1-weighted (T1W) coronal VRS developed by Scheltens et al. However, it is often difficult to use the T1W-coronal VRS in cases with limitations in obtaining T1W-coronal images. To overcome this issue, we modified the T1W-coronal VRS onto the axial plane. Objective: The purposes of this study were to validate our T1W-axial VRS by examining its compatibility with the original T1W-coronal VRS and by investigating the correlation with the cognitive functions and hippocampal volumes. Methods: Participants were 50 patients with Alzheimer's disease dementia and 30 elderly with normal cognition. We transposed each component of the T1W-coronal VRS onto T1W-axial images (i.e., the largest height of the hippocampal formation into the width of the medial temporal lobe). The compatibility of T1W-axial VRS with T1W-coronal one was determined using the kappa value. The correlations of T1W-axial VRS with cognitive performance or the hippocampal volumes were analyzed with age, gender, and education as covariates. Results: The kappa value between the T1W-axial and T1W-coronal VRS was 0.772 (p < 0.045). The T1W-axial VRS showed a significant correlation with the scores of cognitive functions, including verbal memory tests (-0.601, p < 0.001 for the left). Furthermore, the T1W-axial VRS also correlated well with hippocampal volumes (-0.576, p < 0.001). Conclusions: The T1W-axial VRS showed good agreement with T1W-coronal VRS and correlated well with cognitive functions as well as hippocampal volumes, which suggests that the T1-axial VRS may replace the original T1W-coronal one.
URI
https://content.iospress.com/articles/journal-of-alzheimers-disease/jad132333http://hdl.handle.net/20.500.11754/53877
ISSN
1387-2877
DOI
10.3233/JAD-132333
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE