213 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김경헌-
dc.date.accessioned2018-03-28T07:47:32Z-
dc.date.available2018-03-28T07:47:32Z-
dc.date.issued2012-12-
dc.identifier.citationKorean Journal of Anesthesiology, 2012, 63권, 6호, pp.510-514en_US
dc.identifier.issn0302-5780-
dc.identifier.urihttps://ekja.org/journal/view.php?number=7469-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/53370-
dc.description.abstractBackground: The relatively recently developed I-gel (Intersurgical Ltd., Workingham, England) is a supraglottic airway device designed for single-use that, unlike conventional LMAs, does not require an inflatable cuff. In addition, the I-gel, much like the Proseal LMA (PLMA), has a gastric drainage tube associated with an upper tube for decompression of the stomach, thereby avoiding acid reflux and decreasing the risk of pulmonary absorption. The purpose of this study was to compare PLMA and I-gel devices in patients undergoing gynecological laparoscopy based on sealing pressure before and during pneumoperitoneum, insertion time, and gas exchange. Methods: Following Institutional Review Board approval and written informed consent, 30 adult patients were randomly allocated to one of two groups (the PLMA or I-gel group). In each case, insertion time and number of attempts were recorded. After successful insertion, airway leak pressure was measured. Results: Successful insertion and mechanical ventilation with both supraglottic airway devices was achieved on the first attempt in all 30 patients, and there were no significant differences with respect to insertion time. Likewise, leak pressure did not vary significantly either between or within groups after CO2 insufflation. In addition, differences between leak volume and leak fraction between groups were not significant. Conclusions: The results of our study indicate that the I-gel is a reasonable alternative to the PLMA for controlled ventilation during laparoscopic gynecologic surgery. (Korean J Anesthesiol 2012; 63: 510-514)en_US
dc.language.isoenen_US
dc.publisher대한마취통증의학회en_US
dc.subjectI-gelen_US
dc.subjectPLMAen_US
dc.titleComparison of the Proseal LMA and intersurgical I-gel during gynecological laparoscopyen_US
dc.typeArticleen_US
dc.relation.no6-
dc.relation.volume63-
dc.identifier.doi10.4097/kjae.2012.63.6.510-
dc.relation.page510-514-
dc.relation.journalKorean Journal of Anesthesiology-
dc.contributor.googleauthorJeon, Woo-Jae-
dc.contributor.googleauthorCho, Sang-Yun-
dc.contributor.googleauthorBaek, Seong-Jin-
dc.contributor.googleauthorKim, Kyoung-Hun-
dc.relation.code2012231756-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidkimkhun-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE