757 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author지남용-
dc.date.accessioned2018-03-19T07:15:47Z-
dc.date.available2018-03-19T07:15:47Z-
dc.date.issued2012-04-
dc.identifier.citation한국건축시공학회지, Apr 2012, 12(2), P.194-202, 9P.en_US
dc.identifier.issn1598-2033-
dc.identifier.issn2233-5706-
dc.identifier.urihttp://koreascience.or.kr/article/ArticleFullRecord.jsp?cn=GCSGBX_2012_v12n2_194-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/49009-
dc.description.abstractThis paper predicts the cementing efficiency of fly-ash(FA) based on mortar test considering binder-water ratio and FA replacement ratio as experimental variables. The cementing efficiency prediction model proposed by statistical analysis enables us to estimate the value according to the binder-water ratio and FA replacement ratio of matrix. When FA replacement ratio is the same, the lower the binder-water ratio, the higher the estimated cementing efficiency. There are significant differences in the values according to binder-water ratio at FA replacement ratios of 15% or less, but there are almost no differences when FA replacement ratio is more than 15%. As the binder-water ratio increases, the variations in the values according to FA replacement ratio are great at FA replacement ratios of 15% or less. As the FA replacement ratios increase, the values increase for FA replacement ratios of 15% or less, but decrease for more than 15%. The values range from -0.71 to 1.24 at binder-water ratio of 1.67-2.86 and FA replacement ratio of 0-70%. The RMSE of the 28-day compressive strength predicted by modified water-cement ratio is 2.2 MPa. The values can be trusted, as there is good agreement between predicted strength and experimental strength.en_US
dc.language.isoenen_US
dc.publisher한국건축시공학회en_US
dc.subjectfly-ashen_US
dc.subjectcementing efficiencyen_US
dc.subjectrelative strengthen_US
dc.subjectmodified cement-water ratioen_US
dc.subjectstrength predictionen_US
dc.titleCementing Efficiency of Fly-ash in Mortar Matrix According to Binder-Water Ratio and Fly-ash Replacement Ratioen_US
dc.typeArticleen_US
dc.relation.no2-
dc.relation.volume12-
dc.identifier.doi10.5345/JKIBC.2012.12.2.194-
dc.relation.page194-202-
dc.relation.journal한국건축시공학회지-
dc.contributor.googleauthorCho, Hong-Bum-
dc.contributor.googleauthorJee, Nam-Yong-
dc.relation.code2012233427-
dc.sector.campusS-
dc.sector.daehakOFFICE OF ACADEMIC AFFAIRS[S]-
dc.sector.departmentCENTER FOR INTEGRATED GENERAL EDUCATION-
dc.identifier.pidnyjee-
Appears in Collections:
OFFICE OF ACADEMIC AFFAIRS[S](교무처) > ETC
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE