214 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김성환-
dc.date.accessioned2018-03-17T05:01:47Z-
dc.date.available2018-03-17T05:01:47Z-
dc.date.issued2014-09-
dc.identifier.citationKnee Surgery & Related Research, Sep 2014, 26(3), p141-148. 8p.en_US
dc.identifier.issn2234-0726-
dc.identifier.urihttp://eds.b.ebscohost.com/eds/detail/detail?vid=0&sid=1afe2101-e087-48f5-b737-59f877850104%40sessionmgr103&bdata=Jmxhbmc9a28mc2l0ZT1lZHMtbGl2ZQ%3d%3d#db=a9h&AN=97894222-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/48302-
dc.description.abstractPurpose: We hypothesized that the low contact stress (LCS) posterior stabilization system in knees with ≤3° deviation of coronal alignment would provide more favorable clinical outcomes and survival rate over the course of time. Materials and Methods: A retrospective study was performed on 253 consecutive cases of primary total knee arthroplasty (TKA). Patients were classified according to the degree of deviation of coronal alignment on the initial postoperative radiograph as Group 1 (≤3° deviation) and Group 2 (>3° deviation). The clinical assessments were performed using the Knee Society score and Hospital for Special Surgery systems and Western Ontario and McMaster Universities index. Results: The survival rate was 97.4% in Group 1 and 96.8% in Group 2. No statistically significant intergroup difference was observed in the clinical scores before surgery and since 1 year after surgery (p>0.05). However, a significant intergroup difference was noted between 6 months to 1 year after surgery (p<0.001). Less than 2 mm radiolucent lines were found more frequently in Group 2. Time-dependent improvement was noted within one year after TKA in both groups. Conclusions: Most of the expected improvements were achieved at 6 months after surgery in Group 1 and at 1 year after surgery in Group 2. The present study suggests that the LCS system yields time-dependent improvement regardless of coronal alignment deviation. [ABSTRACT FROM AUTHOR]en_US
dc.language.isoenen_US
dc.publisher대한슬관절학회en_US
dc.subjectArthroplastyen_US
dc.subjectKneeen_US
dc.subjectTreatment outcomeen_US
dc.titleTime-dependent clinical results of rotating-platform total knee arthroplasty according to mechanical axis deviation.en_US
dc.typeArticleen_US
dc.identifier.doi10.5792/ksrr.2014.26.3.141-
dc.relation.journalKnee Surgery and Related Research-
dc.contributor.googleauthorLee, Han-Jun-
dc.contributor.googleauthorJung, Ho-Joong-
dc.contributor.googleauthorJung, Young-Bok-
dc.contributor.googleauthorKo, Young-Bong-
dc.contributor.googleauthorSong, Min-Ku-
dc.contributor.googleauthorKim, Seong-Hwan-
dc.relation.code2014001999-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidksh170177-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE