235 0

Cerebral microbleeds are associated with nocturnal reverse dipping in hypertensive patients with ischemic stroke

Title
Cerebral microbleeds are associated with nocturnal reverse dipping in hypertensive patients with ischemic stroke
Author
김영서
Keywords
Ambulatory blood pressure monitoring; Cerebral microbleeds; Cerebrovascular disease; Cerebral ischemia; Hypertension
Issue Date
2014-01
Publisher
BIOMED CENTRAL LTD
Citation
BMC NEUROLOGY; JAN 12 2014, 14, 7p.
Abstract
Background: Abnormalities in nocturnal blood pressure dipping are well known for its relationship to cardiovascular diseases. Cerebral microbleeds are frequently observed in patients with hypertension and are known to be potent risk factors for stroke. However, there are scanty reports about the relationship between nocturnal dipping and cerebral microbleeds. Methods: We recruited consecutive patients with both hypertension and ischemic stroke within 7 days after symptom onset, and those with cardioembolism were excluded. We applied 24-hour ambulatory blood pressure monitoring two weeks after stroke onset, and we used brain MRI to detect cerebral microbleeds. Various blood pressure parameters such as mean 24-hour blood pressure, awake/sleep blood pressure, and morning surge were compared between cerebral microbleeds (+) vs. (-) groups. Subjects were further classified according to nocturnal dipping status and were analyzed by logistic regression to determine its association with cerebral microbleeds with adjustment for age, gender, and cardiovascular risk factors. Results: A total of 162 patients (100 males, age 65.33 +/- 10.32 years) were included. Cerebral microbleeds were detected in 65 patients (40.1%). Most ambulatory blood pressure parameters except morning surge were significantly higher in those who had cerebral microbleeds. After adjusting for the confounding factors, the reverse dippers were prone to have cerebral microbleeds (odds ratio, 3.81; 95% confidential interval, 1.36-10.65; p-value = 0.01). Conclusion: Cerebral microbleeds are independently associated with reverse dipping on ambulatory blood pressure monitoring in hypertensive stroke patients.
URI
https://bmcneurol.biomedcentral.com/articles/10.1186/1471-2377-14-8http://hdl.handle.net/20.500.11754/46677
ISSN
1471-2377
DOI
10.1186/1471-2377-14-8
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE