222 0

Contact resistance properties of electron-beam-cured anisotropic conductive films

Title
Contact resistance properties of electron-beam-cured anisotropic conductive films
Author
김재용
Keywords
ACF; Epoxy curing; Electron beam; Irradiation; Contact resistance; FLIP-CHIP; COMPOSITES; PACKAGES
Issue Date
2013-10
Publisher
KOREAN PHYSICAL SOC, 635-4, YUKSAM-DONG, KANGNAM-KU, SEOUL 135-703, SOUTH KOREA
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63(7), P.1477-1480
Abstract
An anisotropic conductive film (ACF) is a thin adhesive epoxy layer that is widely used to connect circuits in highly-integrated electronic devices. To bind two electric circuits, an ACF is pasted between the circuits and pressed with an optimum pressure so that the joints can be electronically connected. For the curing of the resin, electron-beam (E-beam) irradiation is known to be an environmentally friendly technique and exhibits many technical advantages over conventional thermal curing in terms of low temperature and reduced curing time. In this method, the applied pressure and electron-beam dose are critical parameters to maximize the conductivity without a failing of the connection between the circuits. For the minimization of the contact resistance after curing by using E-beam irradiation, curable epoxy resin was mixed with conductive particles made of Ni/Au-plated polymer spheres with a mean particle size of 10 A mu m in a ratio of 5: 1 by weight. The mixed resin was pasted on rigid boards having circuits of 100-A mu m pitch and was irradiated by using an E-beam. The optimum dose for E-beam irradiation for a reasonable curing, the contact resistance values, and the reliability of the cured film were systematically investigated as functions of E-beam dose, applied pressure and temperature. The lowest contact resistance values were obtained when the specimens were irradiated by an 80-kGy E-beam under a constant pressure of 5 kgf/cm(2). At this condition, the minimum contact resistance was 80 +/- 0.015 m Omega, which is significantly lower than the values obtained from commercial products, and the values were maintained within a 5% increase when the samples were kept at 100 A degrees C for 294 hours. Our results demonstrate that an E-beam irradiation technique can be applied for curing ACFs for commercial electronic devices.
URI
http://link.springer.com/article/10.3938%2Fjkps.63.1477http://hdl.handle.net/20.500.11754/44463
ISSN
0374-4884; 3744-4884
DOI
10.3938/jkps.63.1477
Appears in Collections:
COLLEGE OF NATURAL SCIENCES[S](자연과학대학) > PHYSICS(물리학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE