484 0

e Retinal Nerve Fiber Layer Thickness Measurement Repeatability for Cirrus HD-OCT Retinal Tracking System During Eye Movement

Title
e Retinal Nerve Fiber Layer Thickness Measurement Repeatability for Cirrus HD-OCT Retinal Tracking System During Eye Movement
Author
엄기방
Keywords
glaucoma; optical coherence tomography; retinal nerve fiber layer; retinal tracking
Issue Date
2016-03
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Citation
JOURNAL OF GLAUCOMA, v. 25, NO 3, Page. 214-219
Abstract
Purpose: To investigate the repeatability of peripapillary retinal nerve fiber layer (RNFL) thickness measurements obtained using Cirrus high-definition optical coherence tomographic (Cirrus HDOCT) retinal tracking system during various types of eye movements. Materials and Methods: We included 20 healthy eyes, 40 glaucomatous eyes of elderly patients, and 17 eyes with pathologic nystagmus. For healthy eyes, RNFL thickness measurements were obtained under 3 conditions: (1) without eye movement, fixated on the device's internal target, (2) with horizontal eye movement, and (3) with vertical eye movement during scan acquisition. Each session was performed 3 times with and without the use of the retinal tracking system. The repeatability of RNFL thickness measurements obtained with and without the retinal tracking was compared within each session and among the sessions. Results: In healthy eyes, measurements obtained without the use of a retinal tracking system showed lower repeatability when measurements were obtained with eye movements than without (P ˂ 0.05). However, when retinal tracking system was used, measurement repeatability under conditions with eye movements was similar to that achieved without eye movement (P ˃ 0.05) and higher than that obtained without the use of a retinal tracking system (P ˂ 0.05). In elderly glaucomatous patients, the retinal tacking system did not significantly improve measurement repeatability during fixation (P ˃ 0.05). In eyes with pathologic nystagmus, the tracking system did not follow eye movement and scan acquisition was not processed. Conclusions: Cirrus HD-OCT retinal tracking system may enhance RNFL thickness measurement repeatability under certain, but not all, eye movement conditions.
URI
http://pt.wkhealth.com/pt/re/lwwgateway/landingpage.htm;jsessionid=hhSTCWK2pWyTbGgMSpyLhLc5d8SGFqCqDBBgBGnGVhPwJm1BGC0J!1850456459!181195629!8091!-1?sid=WKPTLP:landingpage&an=00061198-201603000-00032http://hdl.handle.net/20.500.11754/37085
ISSN
1057-0829; 1536-481X
DOI
10.1097/IJG.0000000000000250
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE