231 0

Comparison of volume-controlled and pressure-controlled ventilation using a laryngeal mask airway during gynecological laparoscopy

Title
Comparison of volume-controlled and pressure-controlled ventilation using a laryngeal mask airway during gynecological laparoscopy
Author
전우재
Keywords
Lapraroscopic surgery; LMA; Pressure-controlled ventilation; Volume-controlled ventilation
Issue Date
2011-04
Publisher
Elsevier Science B.V
Citation
Korean Journal of Anesthesiology, 2011, 60(3), P.167-172
Abstract
Background: Several publications have reported the successful, safe use of Laryngeal Mask Airway (LMA)-Classic devices in patients undergoing laparoscopic surgery. However, there have been no studies that have examined the application of volume-controlled ventilation (VCV) or pressure-controlled ventilation (PCV) using a LMA during gynecological laparoscopy. The aim of this study is to compare how the VCV and PCV modes and using a LMA affect the pulmonary mechanics, the gas exchange and the cardiovascular responses in patients who are undergoing gynecological laparoscopy. Methods: Sixty female patients were randomly allocated to one of two groups, (the VCV or PCV groups). In the VCV group, baseline ventilation of the lung was performed with volume-controlled ventilation and a tidal volume of 10 ml/kg ideal body weight (IBW). In the PCV group, baseline ventilation of the lung using pressure-controlled ventilation was initiated with a peak airway pressure that provided a tidal volume of 10 ml/kg IBW and an upper limit of 35 cmH2O. The end-tidal CO2, the peak airway pressures (Ppeak), the compliance, the airway resistance and the arterial oxygen saturation were recorded at T1: 5 minutes after insertion of the laryngeal airway, and at T2 and T3: 5 and 15 minutes, respectively, after CO2 insufflation. Results: The Ppeak at 5 minutes and 15 minutes after CO2 insufflation were significantly increased compared to the baseline values in both groups. Also, at 5 minutes and 15 minutes after CO2 insufflation, there were significant differences of the Ppeak between the two groups. The compliance decreased in both groups after creating the pneumopertoneim (P < 0.05). Conclusions: Our results demonstrate that PCV may be an effective method of ventilation during gynecological laparoscopy, and it ensures oxygenation while minimizing the increases of the peak airway pressure after CO2 insufflation. ⓒ the Korean Society of Anesthesiologists, 2011.
URI
https://ekja.org/journal/view.php?doi=10.4097/kjae.2011.60.3.167
ISSN
2005-6419
DOI
10.4097/kjae.2011.60.3.167
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE