242 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author이광현-
dc.date.accessioned2018-02-03T05:06:45Z-
dc.date.available2018-02-03T05:06:45Z-
dc.date.issued2011-03-
dc.identifier.citationSCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, v. 45, NO 1, Page. 40-44en_US
dc.identifier.issn2000-656X-
dc.identifier.urihttps://www.tandfonline.com/doi/abs/10.3109/2000656X.2010.541755?journalCode=iphs20-
dc.description.abstractThe placement of a headless screw within the scaphoid is important for successful fixation of fractured scaphoids. We ascertained the safe position of a screw using virtual collision experiments on a three-dimensionally reconstructed scaphoid bone and screw model, and applied measured angles to simple radiographs. We used images from computed tomograms of the wrists taken from 13 men to reconstruct a three-dimensional cortical image of the scaphoid. Inside the bone, we inserted a virtually reconstructed Herbert screw model and calculated the safe angle along the long axis of the scaphoid at which the screw did not collide with the bone in any sample, then applied measured safe angles to simple anteroposterior and lateral radiographs. In all experiments, the safe angle between the screw and the anteroposterior scaphoid line (defined from the most distal portion of the scaphoid where it met the capitate to the proximal position where the lunate and capitate meet) ranged from 8 degrees A degrees to 27 degrees A degrees in the anteroposterior view, and the safe angle between the screw and the lateral scaphoid line (defined from the most volar portion of the scaphoid tuberosity to the volar position where the scaphoid faced the radius) ranged from 2 degrees A degrees to 26 degrees A degrees in the lateral view. These ranges can be used as a guide for a safe position of the screw within the scaphoid in volar percutaneous fixation of screws in scaphoid fractures.en_US
dc.description.sponsorshipWe thank biomedical engineering Sung-Min Kim for his assistance with the collision experiments. This study was supported by a grant from the Hanyang University, Seoul, Korea.en_US
dc.language.isoenen_US
dc.publisherTAYLOR & FRANCIS ASen_US
dc.subjectScaphoiden_US
dc.subjectcomputed tomogramen_US
dc.subjectheadless screwen_US
dc.subjectthree-dimensional reconstructionen_US
dc.subjectspatial measurementen_US
dc.titleSpatial measurement for safe placement of screws within the scaphoid using three-dimensional analysisen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume45-
dc.identifier.doi10.3109/2000656X.2010.541755-
dc.relation.page40-44-
dc.relation.journalSCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY-
dc.contributor.googleauthorJung, W. S.-
dc.contributor.googleauthorJung, J. H.-
dc.contributor.googleauthorChung, U. S.-
dc.contributor.googleauthorLee, K. H.-
dc.relation.code2011213781-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidleegh-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE