332 0

Inductance Calculation of Flux Concentrating Permanent Magnet Motor through Nonlinear Magnetic Equivalent Circuit

Title
Inductance Calculation of Flux Concentrating Permanent Magnet Motor through Nonlinear Magnetic Equivalent Circuit
Author
이주
Keywords
Inductance; magnetic equivalent circuit (MEC); permanent magnet motors; traction motors
Issue Date
2015-11
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Citation
IEEE TRANSACTIONS ON MAGNETICS, v. 51, NO 11, Article Number 8204304, Page. 1-4
Abstract
In order to design a permanent magnet synchronous motor (PMSM), the inductance must be computed. In this paper, the flux concentrating PMSM (FCPMSM) is introduced. Calculating the inductance is difficult because of the complex structure of the rotor. Because the rib and the bridge consist of an iron core, they have nonlinear characteristics. In order to obtain the effective value of the inductance, nonlinear characteristics must be considered in a magnetic equivalent circuit (MEC). In this paper, to calculate the inductance of an FCPMSM, the relative permeance of the rotor was analyzed. Then, the dq-axis MEC, including the nonlinear magnetic reluctance, was created using the flux line. Finally, we verified the validity of the proposed inductance calculation method by comparing the results between the finite-element method and the proposed method.
URI
http://ieeexplore.ieee.org/document/7113847/http://hdl.handle.net/20.500.11754/29059
ISSN
0018-9464; 1941-0069
DOI
10.1109/TMAG.2015.2438000
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE