298 0

측정불확도를 고려한 배터리 교환형 전기버스용 접속기 접촉저항 평가에 관한 연구

Title
측정불확도를 고려한 배터리 교환형 전기버스용 접속기 접촉저항 평가에 관한 연구
Other Titles
A Study of Contact Resistance Test Considered with Measurement Uncertainty for Electric Bus Couplers with Battery-Swapping System
Author
이주
Keywords
Electric Bus; Coupler; Durability; Contact Resistance; Measurement Uncertainty
Issue Date
2015-10
Publisher
한국조명.전기설비학회
Citation
조명.전기설비학회논문지, v. 29, NO 10, Page. 60-64
Abstract
Many people think that Electric Vehicles(EVs) is the best method to resolve the problems of running out of fossil fuels. But EVs take long time for charging. So, EVs with battery swapping systems(EVBS) are developed to resolve this problem. Nonetheless, EVBS is not spreaded widely because the method of durability test in couplers is not defined. In this study, the evaluation method of durability test in couplers is defined by some standards and the measurement uncertainty is used to increase the reliability of EV couplers.
URI
http://www.dbpia.co.kr/Journal/ArticleDetail/NODE06527652http://hdl.handle.net/20.500.11754/28379
ISSN
1229-4691; 2287-5034
DOI
10.5207/JIEIE.2015.29.10.060
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
There are no files associated with this item.