dc.identifier.citationENERGY AND BUILDINGS, v. 86, Page. 328-339en_US
dc.identifier.issn0378-7788-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/21601-
dc.identifier.urihttp://www.sciencedirect.com/science/article/pii/S0378778814009049-
dc.description.abstractThis paper proposes a server model that can be applied to simulating the annual cooling energy consumption of data centers and an analysis of its impact. Recently, aisle containment architecture and the variable air volume system have been widely adopted in the data center industry because of their superior indoor thermal management and cooling energy savings. However, the current simulation method, which fixes the server heat generation and the supply and return air temperature difference of the computer room air handler (CRAH), does not correctly reflect current cooling systems. In this study, a server model was developed that accounts for server thermal characteristics - including server power, fan airflow, and exhaust temperature - according to the given CPU utilization and temperature. After the proposed server model was validated, the annual cooling energy consumption was simulated for modular data centers with an air-side economizer and high ambient temperature. Unlike the conventional method, the proposed model showed that the cooling energy consumption increased when the CRAH supply air temperature was higher than 19 C because of the increase in fan energy consumption. (C) 2014 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipThis work was supported by a National Research Foundation of Korea (NRF) grant funded by the Korean government (No. 2012001927) and a Korea Evaluation Institute of Industrial Technology grant funded by the Korean government (No. 10045236).-
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE SAen_US
dc.subjectHigh ambient temperatureen_US
dc.subjectEnergy consumption simulationen_US
dc.subjectData centeren_US
dc.subjectServer modelen_US
dc.subjectAir-side economizeren_US
dc.titleSimplified server model to simulate data center cooling energy consumptionen_US
dc.typeArticleen_US
dc.relation.volume86-
dc.identifier.doi10.1016/j.enbuild.2014.10.058-
dc.relation.page328-339-
dc.relation.journalENERGY AND BUILDINGS-
dc.contributor.googleauthorHam, Sang-Woo-
dc.contributor.googleauthorKim, Min-Hwi-
dc.contributor.googleauthorChoi, Byung-Nam-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.relation.code2015008851-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE