24 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author조광현-
dc.date.accessioned2024-07-04T02:37:42Z-
dc.date.available2024-07-04T02:37:42Z-
dc.date.issued2022-11-14-
dc.identifier.citationAPPLIED SCIENCES-BASEL, v. 12, no 22, article no. 11555, page. 1-11en_US
dc.identifier.issn2076-3417en_US
dc.identifier.urihttps://www.mdpi.com/2076-3417/12/22/11555en_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/191138-
dc.description.abstractWith the emergence of the metaverse and other human–computer interaction technologies, promising applications such as medical palpation training are growing for training and education purposes. Thus, the overarching goal of this study is to develop a portable and simple pulse pressure simulator that can reproduce age-specific pulse pressure waveforms for medical palpation training. For training applications, the simulator is required to produce accurate radial pulse waveforms consistently and repeatedly. To this end, exploiting the cam-based pneumatic pulse generation mechanism, this study intends to develop a cylindrical (or 3D) cam whose continually varying surface contains a wide range of age-related pulse pressure profiles. To evaluate the performance of the simulator, the reproduced pulse waveforms were compared with approximate radial pulse pressure waveforms based on in vivo data in terms of the augmentation index (AI) and L2 error. The results show that the errors were less than 10% for all ages, indicating that the proposed pulse simulator can reproduce the age-specific pulse waveforms equivalent to human radial pulse waveforms. The findings in this study suggest that the pulse simulator would be an excellent system for RAPP palpation training as it can reproduce a desired pulse accurately and consistently.en_US
dc.description.sponsorshipThis research was supported by a grant (21174MFDS225) from the Ministry of Food and Drug Safety in 2022.en_US
dc.languageen_USen_US
dc.publisherMDPIen_US
dc.relation.ispartofseriesv. 12, no 22, article no. 11555;1-11-
dc.subjectmedical palpationen_US
dc.subjecthapticsen_US
dc.subjectpulse pressure waveformen_US
dc.subject3D camen_US
dc.titleDevelopment of a Simulator Capable of Generating Age-Specific Pulse Pressure Waveforms for Medical Palpation Trainingen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.3390/app122211555en_US
dc.relation.journalAPPLIED SCIENCES-BASEL-
dc.contributor.googleauthorKim, Dong-Jun-
dc.contributor.googleauthorJo, Gwanghyun-
dc.contributor.googleauthorKoo, Jeong-Hoi-
dc.contributor.googleauthorYang, Tae-Heon-
dc.contributor.googleauthorKim, Young-Min-
dc.relation.code2022039077-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY[E]-
dc.sector.departmentDEPARTMENT OF MATHEMATICAL DATA SCIENCE-
dc.identifier.pidgwanghyun-
Appears in Collections:
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY[E](과학기술융합대학) > ETC
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE