131 55

Performance Enhancement of an MTL Coil Loaded with High-Permittivity Dielectric Liner for 7 T Brain MRI

Title
Performance Enhancement of an MTL Coil Loaded with High-Permittivity Dielectric Liner for 7 T Brain MRI
Author
유형석
Keywords
7 T; dielectric pad; eight-element; MTL transmit array; radio frequency (RF) coil; RF shimming; region of interest
Issue Date
2021-10
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Citation
IEEE ACCESS, v. 9, Page. 144417-144425
Abstract
In a multi-element microstrip transmission line (MTL) transmit array coil, the transmit field (B-1(+)) distribution is inhomogeneous due to its standing-wave nature, and the interference effects can severely degrade the B-1(+) and imaging. Therefore, to improve the homogeneity and strength of B-1(+), this study focuses on the development of a multi-element MTL transmit array coil integrated with a dielectric liner (DL) material. Furthermore, the transmission efficiency (T-x,T-eff ) is improved in the head region. An eight-element MTL transmits array head coil is investigated using thinner DLs, and the optimized dimensions of the DL are found from its resonant mode at 7 Tesla (T). Simulations and measurements are performed with an MTL transmit array coil at 7 T, and the performance is analyzed for the DL positions and dimensions. Remarkably, the proposed DLs-integrated transmit array coil system offered significant improvements in the T(x,eff )at different DLs positions. Compared to the case without the DL, the T-x,T-eff is improved by 9% (DL close to the head model), 15% (DL at center), and 39% (DL close to the RF coil). Interestingly, the DL acts as an efficiency tuner element exhibiting a 9% to 39% T-x,T-eff tuning range of improvement. In addition, the RF-shimming technique improves the Bi F homogeneity and T-x,T-eff of the coil with DLs by 21% and 42%, respectively, compared to the case without the DL. Moreover, the specific absorption rate (SAR) analysis of the MTL transmit array coil with the DLs is performed. The peak 10g-averaged SAR is reduced from 3.1 W/kg to 2.13 W/kg in the head using DLs and RF-shimming technique. Finally, we used the bench measurement setup to obtain the measured magnetic field. The proposed work exhibits salient features with a smaller DL size and multi-element MTL transmit array coil than other proposed works.
URI
https://ieeexplore.ieee.org/document/9584839https://repository.hanyang.ac.kr/handle/20.500.11754/178017
ISSN
2169-3536
DOI
10.1109/ACCESS.2021.3122122
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
Performance Enhancement of an MTL Coil Loaded With High-Permittivity Dielectric Liner for 7 T Brain MRI.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE