110 76

Enhancement and Homogenization of Indoor Air Quality in a Classroom Using a Vertical Airflow Ventilation Scheme

Title
Enhancement and Homogenization of Indoor Air Quality in a Classroom Using a Vertical Airflow Ventilation Scheme
Author
육세진
Keywords
classroom; ventilation; indoor air quality; age of air; computational fluid dynamics
Issue Date
2022-09
Publisher
MDPI
Citation
TOXICS, v. 10, NO. 9, article no. 545, Page. 1-14
Abstract
Since air quality has a great influence on students' health and learning ability, enhancing air quality in classrooms is important. Currently, widely distributed ventilation systems operate by moving airflow horizontally from ventilation inlets and outlets on the ceiling. This method can reduce the average pollution in a space by diluting it through air exchange; however, it is limited regarding homogeneous cleanliness due to air stagnation at some locations. Therefore, in this study, a new ventilation system was devised to improve indoor air quality and spatial homogeneity by installing ventilation inlets on the ceiling and numerous outlets on the floor, creating a vertical airflow in the interior space; this system was then applied to a middle school classroom. Using the age of air as an index, air quality improvement between the existing and newly designed ventilation systems was compared. In the classroom with the existing ventilation system, the age of air was low in the area near the ventilation inlets, while air congestion areas were widely distributed and air age was high near the outlets. Conversely, in the vertical airflow classroom, the average age of air was approximately 15% lower than that with the existing ventilation system, and the deviation of air age for each position in the classroom space was also reduced, showing a uniform air age distribution. Therefore, the vertical airflow ventilation system proposed in this study can be an effective ventilation scheme for enhancing and homogenizing indoor air quality.
URI
https://www.mdpi.com/2305-6304/10/9/545https://repository.hanyang.ac.kr/handle/20.500.11754/177803
ISSN
2305-6304;2305-6304
DOI
10.3390/toxics10090545
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > MECHANICAL ENGINEERING(기계공학부) > Articles