dc.identifier.citation | TOXICS, v. 10, NO. 9, article no. 504, Page. 1-15 | en_US |
dc.identifier.issn | 2305-6304;2305-6304 | en_US |
dc.identifier.uri | https://www.mdpi.com/2305-6304/10/9/504 | en_US |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/177801 | - |
dc.description.abstract | This study targeted a four-bed ward with a ventilation system and a four-way cassette fan coil unit (4-way FCU) installed on the ceiling. The indoor air quality under summer and winter conditions was comparatively analyzed. The age of air was calculated by conducting tests and simulations under diverse conditions, assuming that the ventilation system and 4-way FCU were continuously operating. The use of an air cleaner and ward curtain was investigated for its impact on the air quality in the breathing zone of a patient lying on the bed, and effects of the airflow and discharge angle of the 4-way FCU were considered. Because the 4-way FCU was installed in the central part of the ceiling, where indoor air is sucked in and subsequently discharged in four directions, the age of air at each bed was found to vary depending on the airflow and discharge angle of the 4-way FCU. When the airflow and discharge angle of the 4-way FCU was fixed, the age of air at each bed appeared to be lower during winter heating than in summer cooling mode. The age of air was significantly lowered at each bed, depending on the use of the curtain and the air cleaner along with the ventilation system and 4-way FCU, and appropriate seasonal operating conditions were identified to maintain a lower age of air at each bed. | en_US |
dc.description.sponsorship | This research was conducted under the Reduction Management Program of Fine Dust Blind-Spots and was supported by the Ministry of Environment as part of the Korea Environmental Industry & Technology Institute (KEITI) (No. 2020003060010). | en_US |
dc.language | en | en_US |
dc.publisher | MDPI | en_US |
dc.source | 96477_육세진.pdf | - |
dc.subject | indoor air quality | en_US |
dc.subject | age of air | en_US |
dc.subject | fan coil unit | en_US |
dc.subject | ventilation system | en_US |
dc.subject | air cleaner | en_US |
dc.title | Comparison of Indoor Air Quality in Summer and Winter According to Four-Way Cassette Fan Coil Unit Operation in a Four-Bed Ward | en_US |
dc.type | Article | en_US |
dc.relation.no | 9 | - |
dc.relation.volume | 10 | - |
dc.identifier.doi | 10.3390/toxics10090504 | en_US |
dc.relation.page | 1-15 | - |
dc.relation.journal | TOXICS | - |
dc.contributor.googleauthor | Lee, Jungsuk | - |
dc.contributor.googleauthor | An, Ik-Hyun | - |
dc.contributor.googleauthor | Park, Su-Hoon | - |
dc.contributor.googleauthor | Lee, Kyung-Rae | - |
dc.contributor.googleauthor | Kim, Young-Won | - |
dc.contributor.googleauthor | Yook, Se-Jin | - |
dc.sector.campus | S | - |
dc.sector.daehak | 공과대학 | - |
dc.sector.department | 기계공학부 | - |
dc.identifier.pid | ysjnuri | - |