112 88

Full metadata record

DC FieldValueLanguage
dc.contributor.author김인영-
dc.date.accessioned2022-10-11T07:45:27Z-
dc.date.available2022-10-11T07:45:27Z-
dc.date.issued2021-01-
dc.identifier.citationBIOSENSORS-BASEL, v. 11, NO 2, article no. 35, Page. 1-13en_US
dc.identifier.issn2079-6374en_US
dc.identifier.urihttps://www.mdpi.com/2079-6374/11/2/35en_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/175206-
dc.description.abstractRecently, a smart-device-based chest compression depth (CCD) feedback system that helps ensure that chest compressions have adequate depth during cardiopulmonary resuscitation (CPR) was developed. However, no CCD feedback device has been developed for infants, and many feedback systems are inconvenient to use. In this paper, we report the development of a smart-ring-based CCD feedback device for CPR based on an inertial measurement unit, and propose a high-quality chest compression depth estimation algorithm that considers the orientation of the device. The performance of the proposed feedback system was evaluated by comparing it with a linear variable differential transformer in three CPR situations. The experimental results showed compression depth errors of 2.0 +/- 1.1, 2.2 +/- 0.9, and 1.4 +/- 1.1 mm in the three situations. In addition, we conducted a pilot test with an adult/infant mannequin. The results of the experiments show that the proposed smart-ring-based CCD feedback system is applicable to various chest compression methods based on real CPR situations.en_US
dc.description.sponsorshipThis work was supported by the research fund of Hanyang University (HY-2018).en_US
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.subjectcardiopulmonary resuscitation; inertial measurement units; mobile health; smart ring; chest compressionen_US
dc.titleDevelopment of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Studyen_US
dc.typeArticleen_US
dc.relation.no2-
dc.relation.volume11-
dc.identifier.doi10.3390/bios11020035en_US
dc.relation.page1-13-
dc.relation.journalBIOSENSORS-BASEL-
dc.contributor.googleauthorLee, Seungjae-
dc.contributor.googleauthorSong, Yeongtak-
dc.contributor.googleauthorLee, Jongshill-
dc.contributor.googleauthorOh, Jaehoon-
dc.contributor.googleauthorLim, Tae Ho-
dc.contributor.googleauthorAhn, Chiwon-
dc.contributor.googleauthorKim, In Young-
dc.relation.code2021002336-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidiykim-
dc.identifier.orcidhttps://orcid.org/0000-0001-9580-7074-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE