192 118

Full metadata record

DC FieldValueLanguage
dc.contributor.author이원준-
dc.date.accessioned2022-10-11T04:28:06Z-
dc.date.available2022-10-11T04:28:06Z-
dc.date.issued2021-01-
dc.identifier.citationSCIENTIFIC REPORTS, v. 11, NO 1, article no. 1264en_US
dc.identifier.issn2045-2322en_US
dc.identifier.urihttps://www.nature.com/articles/s41598-020-80321-1en_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/175175-
dc.description.abstractThe present study aimed to identify vibroacoustic properties associated with intraocular pressure (IOP) changes and to suggest a new way to measure the IOP based on these properties. Ten ex vivo porcine eyeballs were used in this study. Each eyeball was fixated in a central hole of a Styrofoam block, and vibration applied to the Styrofoam block was transmitted to the eyeball. An accelerometer directly attached to the eyeball measured the vibration response. Excitations and measurements were performed for 1 s, and the excitation magnitude was varied for the same signal in repeat measurements. A 30-gauge needle was inserted into the anterior chamber of the eyeball to inject a balanced salt solution, and the height of the bottle was adjusted to adjust the IOP. A tonometer was used under identical conditions to measure the IOP five times, and the mean value was determined for further analyses. The measurements showed that the parameters resonance frequency and change in the magnitude of the vibration response (CMVR) increased with rising IOP values. The CMVR was highly correlated with the IOP (p-value < 0.0001). A linear mixed effects model (LMM) was used as a statistical analysis method. We confirmed that vibroacoustic properties of the eyeball are correlated with IOP changes. It is expected that the CMVR will serve as a new parameter for IOP measurements. Thus, in the future, continuous IOP measurements would be easily performed using the CMVR.en_US
dc.description.sponsorshipThis research was supported by the Bio & Medical Technology Development Program of the National Research Foundation (NRF) and funded by the Korean government (MSIT) [Grant number 2019M3E5D1A01069363].en_US
dc.language.isoenen_US
dc.publisherNATURE RESEARCHen_US
dc.titleA pilot study for intraocular pressure measurements based on vibroacoustic parametersen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume11-
dc.identifier.doi10.1038/s41598-020-80321-1en_US
dc.relation.page1-10-
dc.relation.journalSCIENTIFIC REPORTS-
dc.contributor.googleauthorKim, Deukha-
dc.contributor.googleauthorChung, Youngbeen-
dc.contributor.googleauthorYeon, Yeji-
dc.contributor.googleauthorCho, Hyunsoo-
dc.contributor.googleauthorLim, Han Woong-
dc.contributor.googleauthorPark, Junhong-
dc.contributor.googleauthorLee, Won June-
dc.relation.code2021002638-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidwonjunelee-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE