175 76

Diagnostic performance and optimal cut-off values of cardiac biomarkers for predicting cardiac injury in carbon monoxide poisoning

Title
Diagnostic performance and optimal cut-off values of cardiac biomarkers for predicting cardiac injury in carbon monoxide poisoning
Author
허란
Keywords
Carbon monoxide; Poisoning; Echocardiography
Issue Date
2020-09
Publisher
Korean Society of Emergency Medicine
Citation
Clinical and Experimental Emergency Medicine, v. 7, no. 3, page. 183-189
Abstract
Objective This study aimed to compare the diagnostic performance of cardiac biomarkers and to evaluate the optimal cut-off values for echocardiographic cardiac injury prediction in patients with carbon monoxide (CO) poisoning. Methods This retrospective observational cohort study included adult patients with acute CO poisoning. Patients who did not undergo transthoracic echocardiography, which was used to define patients with cardiac injury (ejection fraction < 55%), were excluded. The area under the curve was used to evaluate diagnostic performance for cardiac injury prediction. Mann-Whitney U, chi-square, and Fisher exact tests were used to analyze data. Results After excluding the 27 patients who did not undergo echocardiography, 114 patients were included in the study. Fifteen (13.2%) patients had cardiac injury. The area under the curve values for the B-type natriuretic peptide, creatine kinase-myocardial band, and troponin I were 0.711 (95% confidence interval [CI], 0.527-0.895; P= 0.011), 0.766 (95% CI, 0.607-0.926; P= 0.001), and 0.801 (95% CI, 0.647-0.955; P< 0.001), respectively, with optimal cut-off values of 330 pg/mL, 10.1 ng/mL, and 0.455 ng/mL, respectively. The sensitivity, specificity, and positive and negative predictive values of troponin I were 67%, 91%, 53%, and 95%, respectively. Conclusion Troponin I showed the best diagnostic performance for predicting cardiac injury in patients with CO poisoning. A cut-off value of 0.455 ng/mL appeared optimal for cardiac injury prediction. However, further studies on cardiac biomarkers and other diagnostic tools in CO poisoning are needed given the low sensitivity of troponin I.
URI
https://www.ceemjournal.org/journal/view.php?doi=10.15441/ceem.19.072https://repository.hanyang.ac.kr/handle/20.500.11754/170495
ISSN
2383-4625
DOI
10.15441/ceem.19.072
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
Diagnostic performance and optimal cut-off values of cardiac biomarkers for predicting cardiac injury in carbon monoxide poisoning.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE