181 63

Full metadata record

DC FieldValueLanguage
dc.contributor.author강보경-
dc.date.accessioned2022-04-18T07:10:08Z-
dc.date.available2022-04-18T07:10:08Z-
dc.date.issued2020-08-
dc.identifier.citationKOREAN JOURNAL OF RADIOLOGY, v. 21, no. 8, page. 987-997en_US
dc.identifier.issn1229-6929-
dc.identifier.issn2005-8330-
dc.identifier.urihttps://kjronline.org/DOIx.php?id=10.3348/kjr.2020.0237-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/170096-
dc.description.abstractObjective: Measurement of the liver and spleen volumes has clinical implications. Although computed tomography (CT) volumetry is considered to be the most reliable noninvasive method for liver and spleen volume measurement, it has limited application in clinical practice due to its time-consuming segmentation process. We aimed to develop and validate a deep learning algorithm (DLA) for fully automated liver and spleen segmentation using portal venous phase CT images in various liver conditions. Materials and Methods: A DLA for liver and spleen segmentation was trained using a development dataset of portal venous CT images from 813 patients. Performance of the DLA was evaluated in two separate test datasets: dataset-1 which included 150 CT examinations in patients with various liver conditions (i.e., healthy liver, fatty liver, chronic liver disease, cirrhosis, and post-hepatectomy) and dataset-2 which included 50 pairs of CT examinations performed at ours and other institutions. The performance of the DLA was evaluated using the dice similarity score (DSS) for segmentation and Bland-Altman 95% limits of agreement (LOA) for measurement of the volumetric indices, which was compared with that of ground truth manual segmentation. Results: In test dataset-1, the DLA achieved a mean DSS of 0.973 and 0.974 for liver and spleen segmentation, respectively, with no significant difference in DSS across different liver conditions (p = 0.60 and 0.26 for the liver and spleen, respectively). For the measurement of volumetric indices, the Bland-Altman 95% LOA was-0.17 +/- 3.07% for liver volume and-0.56 +/- 3.78% for spleen volume. In test dataset-2, DLA performance using CT images obtained at outside institutions and our institution was comparable for liver (DSS, 0.982 vs. 0.983; p = 0.28) and spleen (DSS, 0.969 vs. 0.968; p = 0.41) segmentation. Conclusion: The DLA enabled highly accurate segmentation and volume measurement of the liver and spleen using portal venous phase CT images of patients with various liver conditions.en_US
dc.description.sponsorshipThis research was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (2020R1F1A1048826) and the Bio and Medical Technology Development Program of the NRF, which is funded by the Ministry of Science and ICT (NRF-2016M3A9A7918706).en_US
dc.language.isoenen_US
dc.publisherKOREAN RADIOLOGICAL SOCen_US
dc.subjectDeep learningen_US
dc.subjectArtificial intelligenceen_US
dc.subjectLiveren_US
dc.subjectSpleenen_US
dc.subjectSegmentationen_US
dc.subjectVolumetryen_US
dc.titleDeep Learning Algorithm for Automated Segmentation and Volume Measurement of the Liver and Spleen Using Portal Venous Phase Computed Tomography Imagesen_US
dc.typeArticleen_US
dc.relation.no8-
dc.relation.volume21-
dc.identifier.doi10.3348/kjr.2020.0237-
dc.relation.page987-997-
dc.relation.journalKOREAN JOURNAL OF RADIOLOGY-
dc.contributor.googleauthorAhn, Yura-
dc.contributor.googleauthorYoon, Jee Seok-
dc.contributor.googleauthorLee, Seung Soo-
dc.contributor.googleauthorSuk, Heung-Il-
dc.contributor.googleauthorSon, Jung Hee-
dc.contributor.googleauthorSung, Yu Sub-
dc.contributor.googleauthorLee, Yedaun-
dc.contributor.googleauthorKang, Bo-Kyeong-
dc.contributor.googleauthorKim, Ho Sung-
dc.relation.code2020049823-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidmsbbogri-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE