312 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김진수-
dc.date.accessioned2021-12-23T04:17:42Z-
dc.date.available2021-12-23T04:17:42Z-
dc.date.issued2021-01-
dc.identifier.citationCIRP JOURNAL OF MANUFACTURING SCIENCE AND TECHNOLOGY, v. 32, Page. 277-286en_US
dc.identifier.issn1755-5817-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1755581721000092-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/167017-
dc.description.abstractThe gas in polymer melt during injection molding includes various chemical substances that leave deposits on the vent, which leads to a clogged vent. The predictive maintenance of the vent is necessary to prevent the sudden generation of defects and the unexpected downtime of the process due to vent clogging. Hence, it is necessary to monitor the state of the vent. In this study, we propose cavity-gas-pressure (CGP) and cavity-gas-temperature (CGT) sensors as monitoring sensors and evaluate the feasibility of the sensors for monitoring vent clogging. The CGP and the CGT sensors measure the pressure and the temperature changes of the cavity gas respectively when the gas is compressed at the end of the filling. To examine the monitoring capability of the sensors, three sets of tests were conducted: a sensitivity test, an influence test of processing conditions, and a reliability test in a long-cycle run. The sensors were installed in a spiral mold with an interchangeable vent block of various depths in the experiments. Although the CGP and the CGT sensors exhibited sufficient sensitivity to detect vent depth differences, the CGP sensor showed higher sensitivity. In the influence test, processing conditions, such as the injection speed, metering value, melt temperature, and cooling time were examined with respect to PE and TE. In the reliability test in a long-cycle run, only the CGP sensor was tested. The CGP sensor produced a reliable result over 550 cycles, which proved that the sensor is a feasible sensor for monitoring vent clogging.en_US
dc.language.isoen_USen_US
dc.publisherELSEVIERen_US
dc.subjectInjection moldingen_US
dc.subjectVent cloggingen_US
dc.subjectvent monitoringen_US
dc.subjectCavity gas sensorsen_US
dc.subjectPredictive maintenanceen_US
dc.titleDevelopment of the vent clogging monitoring methods for injection moldingen_US
dc.typeArticleen_US
dc.relation.volume32-
dc.identifier.doi10.1016/j.cirpj.2021.01.009-
dc.relation.page277-286-
dc.relation.journalCIRP JOURNAL OF MANUFACTURING SCIENCE AND TECHNOLOGY-
dc.contributor.googleauthorKim, Bongju-
dc.contributor.googleauthorHan, Eunsu-
dc.contributor.googleauthorRhee, Byungohk-
dc.contributor.googleauthorGim, Jinsu-
dc.relation.code2021002255-
dc.sector.campusE-
dc.sector.daehakRESEARCH INSTITUTE[E]-
dc.sector.departmentRESEARCH INSTITUTE OF ENGINEERING & TECHNOLOGY-
dc.identifier.pidjinsugim-
Appears in Collections:
RESEARCH INSTITUTE[E](부설연구소) > RESEARCH INSTITUTE OF ENGINEERING & TECHNOLOGY(공학기술연구소) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.