253 0

Shoulder outcome scoring systems have substantial ceiling effects 2 years after arthroscopic rotator cuff repair

Title
Shoulder outcome scoring systems have substantial ceiling effects 2 years after arthroscopic rotator cuff repair
Author
이봉근
Keywords
Arthroscopic rotator cuf repair; Simple shoulder test; American shoulder and elbow surgeons score; University of California at Los Angeles shoulder rating scale; Constant–Murley shoulder score; Ceiling effect
Issue Date
2020-05
Publisher
SPRINGER
Citation
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, v. 29, no. 7, page. 2070-2076
Abstract
Purpose Previous studies show no difference in clinical outcomes between patients with healed and structurally failed rotator cuff repairs. The objective of this study was to assess ceiling effects when reporting surgical outcomes of arthroscopic rotator cuff repair using four of the currently most popular clinical shoulder outcome scoring systems. Methods Ninety-two patients who underwent arthroscopic rotator cuff repair were examined. The simple shoulder test (SST), American Shoulder and Elbow Surgeons (ASES) score, University of California at Los Angeles (UCLA) shoulder rating scale, and Constant-Murley shoulder score were completed 2 years postoperatively. Demographic data of the subjects were analysed using descriptive statistics. The ceiling effects in the outcome data assessed for each scale were estimated based on two previously reported definitions. Results The number of patients with the maximum possible score was 31 (33.7%) with the SST, 26 (28.3%) with the ASES score, 28 (30.4%) with the UCLA scale, and 18 (19.6%) with the Constant-Murley score. The standardised distance of the outcome data assessed by the SST, ASES score, UCLA scale, and Constant-Murley scores were 0.92, 0.97, 0.96, and 1.18, respectively. Conclusion The SST, ASES score, and UCLA scale evaluated at 2 years postoperatively have substantial ceiling effects showing that the proportion of patients with the maximum possible score is ˃ 20%, and the standardised distance is ˂ 1.0. Researchers should be aware of possible biases due to ceiling effects when interpreting the results of studies investigating the surgical outcomes of arthroscopic rotator cuff repair. It could increase the likelihood of a type II error.
URI
https://link.springer.com/article/10.1007%2Fs00167-020-06036-yhttps://repository.hanyang.ac.kr/handle/20.500.11754/166723
ISSN
0942-2056; 1433-7347
DOI
10.1007/s00167-020-06036-y
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE