Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김민기 | - |
dc.date.accessioned | 2021-11-02T07:51:18Z | - |
dc.date.available | 2021-11-02T07:51:18Z | - |
dc.date.issued | 2020-04 | - |
dc.identifier.citation | WORLD JOURNAL OF SURGERY, v. 44, no. 4, page. 1302-1308 | en_US |
dc.identifier.issn | 0364-2313 | - |
dc.identifier.issn | 1432-2323 | - |
dc.identifier.uri | https://link.springer.com/article/10.1007%2Fs00268-019-05336-w | - |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/166154 | - |
dc.description.abstract | Background The aim of this study was to compare the perioperative outcomes when using a micropuncture access set (MS) to those when using a conventional puncture set (CS) for implantation of totally implantable venous access device (TAVID). Methods A total of 314 patients undergoing chemotherapy for colorectal cancer were included between June 2015 and July 2018. Of these, 123 (39.2%) received TAVID implantation using MS and 191 patients (60.8%) received TAVID using CS. Perioperative outcomes and complications were compared between both groups. Results Baseline characteristics, including body mass index, American Society of Anesthesiologists score, cardiovascular disease, diabetes mellitus, and hyperlipidemia, were not significantly different between the groups. Postoperative complications occurred in 25 patients (8.0%), and the rate and incidence of venous thrombosis were significantly higher in the CS group. There were no significant differences between the groups in other complications such as the rate of port site infection, deep vein thrombosis, obstruction, catheter dislocation, and skin complications (exposure). No incidence of catheter infection, port rotation, intraoperative bleeding, or pneumothorax was observed in this cohort. Conclusions MS is a safe and feasible procedure and results in less thrombosis. MS may play an important role in improving outcomes for the implantation of TAVID. | en_US |
dc.language.iso | en | en_US |
dc.publisher | SPRINGER | en_US |
dc.subject | RADIOLOGIC PLACEMENT | en_US |
dc.subject | COMPLICATIONS | en_US |
dc.subject | THROMBOSIS | en_US |
dc.subject | VEIN | en_US |
dc.subject | PORT | en_US |
dc.title | Micropuncture Access Set Use During Implantation of Totally Implantable Venous Access Device May Reduce Upper Extremity DVT Incidence Among Patients Undergoing Chemotherapy for Colorectal Cancer | en_US |
dc.type | Article | en_US |
dc.relation.no | 4 | - |
dc.relation.volume | 44 | - |
dc.identifier.doi | 10.1007/s00268-019-05336-w | - |
dc.relation.page | 1302-1308 | - |
dc.relation.journal | WORLD JOURNAL OF SURGERY | - |
dc.contributor.googleauthor | Lee, Chul Seung | - |
dc.contributor.googleauthor | Yoon, Sung-Hoon | - |
dc.contributor.googleauthor | Lee, Seung-Min | - |
dc.contributor.googleauthor | Lee, In Kyu | - |
dc.contributor.googleauthor | Kim, Jang Young | - |
dc.contributor.googleauthor | Cho, Hyun Min | - |
dc.contributor.googleauthor | Kim, Min Ki | - |
dc.relation.code | 2020051284 | - |
dc.sector.campus | S | - |
dc.sector.daehak | COLLEGE OF MEDICINE[S] | - |
dc.sector.department | DEPARTMENT OF MEDICINE | - |
dc.identifier.pid | arrokim | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.